17.2) TABLE A: DIP SWITCH
DIP
Default
De nition
TCA- Automatic
ON
closing time.
ON
OFF
OFF
steps.
OFF
RADIO LEARN -
OFF
Transmitter program-
ming.
OFF
or 2nd radio channel.
OFF
FAST CLOSE
18
- MOOVI 30-50 - ALPHA BOM
INSTALLATION MANUAL
Cross out
setting
Description
used
Automatic closing ON.
ON
OFF
Automatic closing OFF.
ON
OFF
ON
START commands not accepted during opening.
OFF
START commands accepted during opening.
Switches to 3-step logic.
ON
OFF
Switches to 4-step logic.
ON
OFF
Activates built-in receiver in rolling-code mode.
ON
Disables wireless memorizing of transmitters. Transmitters are memorized only by means of
OFF
manual programming.
ON
Activates relay output as 2nd radio channel.
OFF
ON
Closes barrier after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Command not enabled.