Télécharger Imprimer la page

ITC FERTIC Mode D'emploi page 18

Publicité

6.MAINTENANCE
6.MAINTENANCE
GB
GB
Clean the fertilizer suction and pressure inlet filters.
Clean the fertilizer suction and pressure inlet filters.
At the end of season, or if very aggressive or precipitable liquids have been
At the end of season, or if very aggressive or precipitable liquids have been
injected, the pump must be cleaned by injecting clean water thought the pump to
injected, the pump must be cleaned by injecting clean water thought the pump to
the irrigation network.
the irrigation network.
PROBLEM
PROBLEM
THE PUMP WORKS BUT
THE PUMP WORKS BUT
DOES NOT INJECT
DOES NOT INJECT
FERTILIZER IS LOST
FERTILIZER IS LOST
THROUGH THE OUTLET
THROUGH THE OUTLET
THE PUMP DOES NOT
THE PUMP DOES NOT
WORK
WORK
PUMP DRAINS IN EXCESS
PUMP DRAINS IN EXCESS
PUMP WORKS MORE
PUMP WORKS MORE
SLOWLY THAN USUAL
SLOWLY THAN USUAL
CAUSE
CAUSE
IRRIGATION VALVE CLOSED
IRRIGATION VALVE CLOSED
DIRTY FERTILIZER FILTER
DIRTY FERTILIZER FILTER
SUCTION OR IMPULSION
SUCTION OR IMPULSION
RETENTION VALVES DIRTY OR
RETENTION VALVES DIRTY OR
DAMAGED
DAMAGED
COLLAR WORN OUT
COLLAR WORN OUT
COLLAR WORN OUT
COLLAR WORN OUT
CYLINDER DAMAGED
CYLINDER DAMAGED
FERTILIZER SUCTION, INJECTION,
FERTILIZER SUCTION, INJECTION,
PRESSURE INLET OR
PRESSURE INLET OR
REGULATION TURRET VALVES
REGULATION TURRET VALVES
CLOSED
CLOSED
LACK OF WATER PRESSURE
LACK OF WATER PRESSURE
DRAINAGE CLOSET
DRAINAGE CLOSET
DRAINAGE LEVEL HIGHER THAT
DRAINAGE LEVEL HIGHER THAT
THE PUMP
THE PUMP
COLLAR WORN OUT
COLLAR WORN OUT
REGULATION TURRET OR
REGULATION TURRET OR
WORKING VALVES ALMOST
WORKING VALVES ALMOST
CLOSED
CLOSED
DIRTY FILTERS
DIRTY FILTERS
18
18
SOLUTION
SOLUTION
OPEN IT
OPEN IT
CLEAN IT
CLEAN IT
THEY MUST BE
THEY MUST BE
DISASSEMBLED AND
DISASSEMBLED AND
CLEANED OR CHANGED,
CLEANED OR CHANGED,
AND ASSEMBLED AGAIN AS
AND ASSEMBLED AGAIN AS
INDICATED IN THE FIGURE
INDICATED IN THE FIGURE
CHANGE IT
CHANGE IT
CHANGE IT
CHANGE IT
OPEN THEM
OPEN THEM
WORKING PRESSURE 1TO
WORKING PRESSURE 1TO
12 BAR 14 TO174PSI
12 BAR 14 TO174PSI
UNBLOC IT
UNBLOC IT
DRAINAGE LEVEL CAN NOT
DRAINAGE LEVEL CAN NOT
BE ABOVE THE PUMP LEVE
BE ABOVE THE PUMP LEVE
CHANGE THEM
CHANGE THEM
OPEN THEM
OPEN THEM
CLEAN THEM
CLEAN THEM

Publicité