Télécharger Imprimer la page

Liability Exclusion; Technical Data - Phocos MPPT100/30 Guide De L'utilisateur

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Liability Exclusion

The manufacturer shall not be liable for damages, especially on the battery, caused by use other than as
intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are
neglected. The manufacturer shall not be liable if there has been service or repair carried out by any
unauthorized person, unusual use, incorrect installation, or poor system design.
Opening the case voids the warranty.

Technical Data

Type
Nominal Voltage
Nominal Battery Charge Current
Max. Solar Input Voltage Voc
Min. Solar Input Voltage Vmp
Max. PV Input Power
Max. Battery Charge Current
Power Conversion Efficiency
Standby Power Consumption
Temperature Compensation
Max. Wire Size
Dimensions
Weight
Ambient Temperature Range
Case Protection
Float Charge
Main Charge
Boost Charge
Equalization
Max. Battery Voltage
Grounding
Battery Type
Subject to change without notice.
Version: 20111202
Made in one of the following countries:
China – Germany
Phocos AG – Germany
www.phocos.com
MPPT100/30
12/24 V, Automatic Recognition
30 A
95 V
> 16/32 V
450 W@12 V, 900 W@24 V
33 A
Max. 98%
< 30 mW @12 V system voltage(< 2 mA)
< 80 mW @24 V system voltage(< 3 mA)
-4 mV/cell*K
32 mm
2
185 x 150 x 115 mm
1.6 kg
-40 to + 50 °C
IP 22
13.8/27.6 V (25 °C)
14.4 V (25 °C), 0.5 h (daily)
14.4/28.8 V (25 °C), 2 h Activation: battery voltage < 12,3/24,6 V
14.8/29.6 V (25 °C), 2 h Activation: battery voltage < 12.1/24.2 V
32 V
Negative grounding
Lead (GEL, AGM, float)
12
ISO9001:2000
RoHS
EN

Publicité

loading