Télécharger Imprimer la page

YORKVILLE EXM Mobile Manuel De L'utilisateur page 5

Publicité

Les langues disponibles

Les langues disponibles

Master Section
Master Control
The Master Control is used to set the overall level of the Yorkville EXM Mobile/Mobile12.
Note: When two systems are linked together, the Master Control only
affects the level of the unit on which it is located.
Effects Selector
Three effects are available with this control, as well as an off (no-effects)
position. The effects are Delay, Hall Reverb and Room Reverb. The selected
effect is available to all 3 input channels and the amount of effect applied
is controlled by the individual channel's effects knob.
Note: If effects are not in use, set this switch to the off position to help
conserve battery life.
Link Section
In situations where additional bass or input channels are needed, The Link jacks
can be used to connect multiple EXM Mobile/Mobile12 systems and/or a subwoofer.
Link Jacks
The Link jacks are in parallel and we have provided both a male and female XLR to
help make it more convenient to 'link' EXM Mobile/Mobile12 enclosures togeth-
er. To use the Link feature, insert a standard XLR patch cable between cabinets.
Battery Status Indicators
The back of the EXM Mobile/Mobile12 has a series of four LEDs (green,
green, yellow, and red) to indicate the approximate charge level. The up-
per green LED is illuminated if there is greater than 85% charge in the
battery. The red LED will begin to blink if the battery is critically low
(approximately 10% remaining) and needs immediate charging.
The indicators will be engaged only when the power switch is turned on.
Low-Power "Sleep" State
In order to preserve battery life, the EXM Mobile/Mobile12 is equipped
with special "sleep" modes. These modes are automatic and nearly unde-
tectable to users when the EXM Mobile/Mobile12 is configured properly.
To ensure the sleep states do not interfere with normal operation, the EXM Mobile/Mobile12 should
always be set up with channel gains set as high as possible (just below clipping) and the output
level should be controlled with the Master control, especially where quiet playback is desired.
Charging Indicator
Whenever AC is connected to the unit, the charging indicator will be turned on. If it is green, the
unit is fully charged. If it is red, the unit is in the process of charging.
Charging the EXM Mobile/Mobile12
To charge the EXM Mobile/Mobile12, plug it into an AC power source using the included power
cord. The charging indicator LED is the best indication of the charging status; even if all of the
battery status LEDs are lit, there is still possibly some additional charging time required.
The EXM Mobile/Mobile12 can be safely left connected to AC power for charging indefinitely. It
will intelligently control its own charging regime when plugged in long-term.
If the EXM Mobile/Mobile12 is going to be stored unused for a long period of time (greater than
one month) it is advisable to periodically plug it in to charge up the battery.
If the EXM Mobile/Mobile12 has been stored for a long period of time unused and it has not been
maintained, it is advisable to connect the charger and leave it plugged in for approximately 24 hours.
The EXM Mobile is delivered with 40-50% of
the charge capacity. Please charge your unit for
5-hours prior to initial battery operation!
3
EXM
Room
Hall
Delay
Off
EFFECTS
LINK
LINK: Used for
connecting inputs
when LINKing
to other powered
speaker cabinets.

Publicité

loading

Ce manuel est également adapté pour:

Exm mobile12