Hoses and Fittings

Installation and Maintenance
Refer to publication 99930323, SAE J1273
(Hose and Hose Assemblies).
Replacement
Refer to a Greenlee Utility catalog or publication
99910322, Low Pressure Quick Couplers, Adapters and
Hoses.
Do not disconnect tool, hoses, or fittings while
the power source is running or if the hydraulic fluid is
hot. Hot hydraulic fluid could cause serious burns.

Typical Setup

Greenlee / A Textron Company
H8508 Series Impact Wrenches

Hose Connections

Tool Port Identification
Match the markings on your tool to this table.
Pressure Port
P
Connecting Hoses
1. Move the flow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Connect the return hose to the return port on the
hydraulic power source, and then to the return port
on the tool.
4. Connect the pressure hose to the pressure port on the
tool, then to the pressure port on the hydraulic power
source.
Disconnecting Hoses
1. Move the flow lever on the hydraulic power source
to the OFF position.
2. Stop the hydraulic power source.
3. Disconnect the pressure hose from the hydraulic
power source, and then from the tool.
4. Disconnect the return hose from the tool, and then
from the hydraulic power source.
5. Install dust caps over the ports to prevent
contamination.