INSTALLATION
Installation
Note
Note the alignment of the wall sleeves.
f Use screws to secure the wall sleeves.
f
f Secure the retainers to the rungs. Do not yet tighten the
f
retainers.
BHE 75-100 Classic
20
| BHE Classic
BHE 175 T Classic
f Guide the retainers into the wall sleeves to join the appliance
f
to the wall.
f Align the appliance.
f
f Tighten the retainer screws and the lock screws.
f
9.3
Hydraulic connection (when integrating into a
DHW/central heating system)
Note
Observe the dimensions and minimum clearances in
chapter "Specification".
f Integrate the appliance into the DHW/central heating system
f
by connecting the flow and return connectors to the on-site
water connections.
f Connect a thermostatic valve at the flow connector.
f
f When filling the appliance, bleed it using the air vent valve.