Lennox EMEA CLIMATIC BALTIC Manuel De Régulation page 90

Table des Matières

Publicité

Afficheur – DS –
Liste Range
0
Pour Régler
1
BALTIC– C
2
Baltic - H
3
Baltic – G
4
Baltic - M
5
Baltic - WH
6
Baltic – WM
7
Baltic - N
8
Baltic - GN
9
Aircool - C
10
Aircool – H
11
Compact - C
12
Compact - H
13
FLEXY – C
14
FLEXY – H
15
FLEXY – G
16
FLEXY – D
17
FLEXY – WH
18
FLEXY – WM
19
FLEXY – N
20
FLEXY – GN
21
FLATAIR – C
22
FLATAIR – H
23
AQUALEAN -C
24
AQUALEAN -H
25
FLEXAIR – C
26
FLEXAIR – H
27
FLEXAIR – G
28
FLEXAIR – D
29
eNeRGy – C
30
eNeRGy – H
31
eNeRGy – WC
32
eNeRGy – WH
33
eNeRGy – N
34
R'Flex – C
35
R'Flex – H
36
R'Flex – G
37
R'Flex – M
38
Fenyx
39
FLATAIR.Adv -M
40
FLATAIR.Adv -S
41
COMPACTAIR Adv -M
42
COMPACTAIR Adv -S
43
AIRCOOLAIR Adv -M
44
AIRCOOLAIR Adv -S
CLIMATIC Roof-Top et Unitaire-IOM-1902-F
List Size
Liste Off On
0
Pour Régler
0
Arrêt □
2
024
1
Marche ●
3
030
4
038
Liste Non Oui
5
042
0
Non □
6
045
1
Oui●
7
052
8
057
List Close Open
9
065
0
Ouvert □
10
075
1
Fermé●
11
085
17
045
List CO
Function
2
18
052
0
0-Min
19
057
1
Min./Max.
20
065
21
075
Liste Inactive Active
22
085
0
Inactif
23
001
1
Actif
24
020
25
025
List Cool Heat
26
030
0
Refroid.
27
035
1
Chauff.
28
040
29
045
List Manuel Auto
30
055
0
Manuel
31
070
1
Auto
32
085
33
100
List Air Water
34
120
0
Air
35
140
1
Eau
36
020
37
025
List Sw BMS
38
030
0
Commutateur
39
035
1
GTC
40
040
41
045
List Unloaded BMS
42
055
0
Non
43
070
1
Délesté
44
085
45
100
List Control Configuration
50
085
0
Ambiance
51
100
1
Soufflage
52
120
53
150
List Heaters 2 Swap Mode
54
170
0
Dernier
55
200
1
Premier
56
230
61
085
List Display Cust SP
62
100
0
Temp.
63
120
1
Décalage
64
150
65
170
List Control Humidity Mode
68
002
0
- Hr% -
69
003
1
- g/kg -
70
004
71
005
List Fresh Air Mini 2
72
010
0
Non
73
012
1
Ext. Basse
74
015
75
020 / 017
List Refrigerant HFO
76
025 / 022
0
R410a
77
030 / 031
1
HFO
79
002
80
003
List Configuration
81
004
0
Non
82
005
1
Oui
83
007
2
Refr.uniquement
84
008
3
PAC
85
010
4
Moduler
86
012
5
Simple
87
015
6
Double
88
018
7
1 Étage
89
020
8
2 étages
90
020
9
3 Étapes
91
025
10
4 étages
92
030
11
100%
93
035
12
500Pa
94
040
13
1000Pa
95
045
14
Statique
96
055
15
Roue
97
070
16
Simple
98
085
17
Tandem
99
100
18
2 vitesses
100
120
19
Air
101
140
20
Eau
102
200
21
Eau et val
103
230
105
004
List Humiditrol Configuration
106
005
0
Non
107
006
1
1 circuit
108
007
2
2 Circuits
109
010
110
012
List Chilled Water Configuration
111
014
0
Non
List Fan Inverter Configuration
List Restore
0
Non
0
1
ATV
1
2
EBM 1
2
Programme
3
EBM 2
3
4
EBM 3
4
Cfg sauvegarder
5
ZA 1
5
Cfg sauvegarde
6
ZA 2
7
ZA 3
List Master/Slaves Function
8
ZA 4
0
9
EBM 4
1
Froid/chaud
10
PWM
2
11
10V
3
Sauvegarde
12
Basse vitesse
4
Sauvegarde.R.
13
Non
5
14
Vanne
List Master/Slaves Function
List Fan Configuration
0
0
.Non réglé
1
1
12-9
2
2
15-11
3
15-11GØ30
List BMS Protocol
4
15-11GØ40
1
5
15-15
2
LennoxVision
6
18-13G
3
7
ADHE-355
4
8
10-10G
5
Courbes de tendances
9
2x18-13
6
BACnet 485
10
K3G450
7
11
K3G500
8
12
K3G560
9
LennoxWeb
13
K3G630
10
14
K3Gxxx
15
GR50C-ZID
List BMS Baud
0
List Motor Configuration
1
0
Non réglé
2
1
0.75-IE1
3
2
1.10-IE1
4
3
1.50-IE1
4
2.20-IE1
List BMS Format
5
3.00-IE1
0
6
4.00-IE1
1
7
5.50-IE1
2
8
7.50-IE1
3
9
9.20-IE1
4
10
11.00-IE1
5
11
0.75-IE2
12
0.95-IE2
Liste schedule Mode
13
1.10-IE2
0
14
1.50-IE2
1
15
2.20-IE2
2
16
3.00-IE2
3
17
4.00-IE2
4
18
5.50-IE2
5
19
7.50-IE2
20
9.20-IE2
List Test
21
11.00-IE2
7
8
Rapidement
List Heaters 1 Configuration
9
0
Non
10
1
Eau
11
2
Gas 1.²
12
3
Gas 2.²
13
4
Gas 1.M
14
5
Gas 2.M
15
6
Détendeur 2
16
7
Élec. M.
17
BM-Y1 10 V
8
Gas 3.²
18
BM-Y2 10 V
9
Gas 4.²
19
BM-Y3 10 V
10
Gas 5.²
20
BM-Y4 10 V
11
Gas 6.²
21
22
List Heaters 2 Configuration
23
B.Nom100 %
0
Non
24
B.bas100 %
1
Détendeur M.
25
2
Eau chaude
26
3
Eau C/F
27
Extraction 1
28
Extraction 2
List Power Meter
29
Extraction 3
0
Non
30
Ventilateur C, C1
1
PM
31
Ventilateur C, C2
2
IEM
32
3
B24
33
34
List Remote Display
35
0
Non
36
1
DC léger
37
2
DC complet
38
3
DM
39
4
DM+DC light
40
5
DM+DC complet
41
42
43
Chauffage C1c1
44
Chauffage C1c2
List Outputs Custom
Non
0
Non utilisé
DC+GTC
1
Alarme NC
2
Alarme NO
USINE
3
Mineure AI
4
Majeure AI
5
Filtre Al
6
Ventilateur AI
7
Comp. Al
Non utilisé
8
Gaz Al
9
Détendeur Al
Comp.Max.
10
Gel. Al
11
Fumée AI
12
Marche/Arrêt
Flow Cas.
13
Dégivrage
14
Chauffage
15
Z. morte
Non utilisé
16
Refroidissement
Maître
17
par GTC
Moyenne
18
Mode Jour I
19
Mode Jour II
20
Mode Jour
Adalink
21
Mode nuit
22
Mode GTC
Modbus
23
Prog. Z0
Lonworks
24
Prog. Z1
25
Prog. Z2
26
Prog. Z3
BACnet IP
27
Prog. Z4
-Carel
28
Prog. Z5
29
Prog. Z6
tEra
30
Room 50%
31
Room 100%
32
Humidif.
1200
33
Pompe
2400
34
Extraction
4800
37
Résistances
9600
38
Ventilateur Cond.
19200
39
Nsr
List Inputs Digital Custom
8-Aucun-2
0
Non utilisé
8-Aucun-1
1
Ambiance Ntc
8-Pair-2
2
Ntc GTC
8-Pair-1
3
Hr. GTC
8-Impair-2
4
Sp Temp.
8-Impair-1
5
Consigne Air neuf
6
Consigne de vitesse
7
T sort.
Init.
8
Temp. ambiante
Jour II
9
Hr. Ext.
Jour I
10
Hr. Ambiance
Jour
11
Qual. air
Nuit
12
Non utilisé
GTC
13
Marche/Arrêt
14
Réinit. alarme
15
400V
.
16
Ventilateur en basse vitesse
17
Ventilateur en grande vitesse
Dégivrage
18
Pas d' Air Neuf
24/24 7/7
19
10% Air Neuf
Assistant
20
20 % Air Neuf
Init. ATV1
21
30 % Air Neuf
Init. ATV2
22
40 % Air Neuf
Init. ATV3
23
50 % Air Neuf
Init. ATV4
24
Tout Air Neuf
Test
25
Sans FreeC
26
Sans FreeH
27
Sans qualité de l'air
28
1/2 Cp.
29
50 % Cp.
BE1-Y 10V
30
Aucun compr.
BE2-Y 10V
31
Aucune PAC
32
1/2 Ht.
33
Chauf. 50 %
B.Nom. 0%
34
Pas de chaleur.
B.bas 0 %
35
Sans Cp. et chal.
36
Chauf. préc.
37
Dégivrage
38
Été
39
Hiver
40
Tcb G
C1c1 Cool
41
Tcb B
C1c2 Cool
42
Tcb Y1
C1-- Froid
43
Tcb Y2
C1-- HP
44
Tcb Y3
C2c1 Cool
45
Tcb Y4
C2c2 Cool
46
Tcb W1
C2-- Froid
47
Tcb W2
C2-- HP
48
pour GTC
C3-- Froid
49
M. Jour II
C3-- HP
50
M. Jour I
C--- Froid
51
M. Jour
52
M. Nuit
53
M. GTC
- 89 -