Empire Heating Systems ULTRASAVER 90 PLUS PVS18N-3 Guide D'utilisation Et Instructions D'installation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Before You Start
1.
Verify there is electrical power to the wall furnace.
Verify the Main Power Switch is turned on. See Figure 1.
If electrical power is present, the red and green control board
LED's will begin to flash alternately. See Figure 3. Each light will
flash four times then the wall furnace will enter standby mode.
While in remote mode, the green LED will flash slowly and the
display panel will show a double dash " - - ". See Figure 2.
If the control board LED's do not activate, verify the wall furnace
is plugged in and the breaker is on. If the wall furnace is still not
activated, contact a qualified service technician.
Page 8
OWNER'S MANUAL
Figure 1
Figure 2
Figure 3
2.
Verify the main gas supply to the unit is on.
The shutoff valve should be in the "OPEN" position. See Figure 4.
Starting the Wall Furnace
The wall furnace has three modes for controlling operation:
Remote, Manual and Local. When in Remote mode, the wall
furnace can be operated by an external Millivolt thermostat,
remote control, or on/off wall switch. When in Manual mode, the
wall furnace can be turned on and off and the heat level adjusted
manually from the display panel. When operating in Local mode,
the owner sets a desired room temperature on the display panel
and the wall furnace will automatically turn on and off and adjust
the heat level to achieve the set temperature.
Wall Furnace Operation - Remote Mode (External Millivolt
Thermostat or Remote)
1.
To initiate the wall furnace Remote mode, press the "Mode
Select" button on the wall furnace display panel once from
OFF mode to display a double dash " - - ". See Figure 5.
CLOSED
OPEN
Figure 4
Figure 5
37873-0-0217