GAMME INDUSTRIE
INDUSTRY LINE
REFROIDISSEURS D'EAU
WATER CHILLERS
ERI
R F C
MANUEL D'INSTALLATION ET D'UTILISATION
INSTALLATION AND OPERATING INSTRUCTIONS
V4.0
MAJ LE 07/11/2012

Publicité

loading

Sommaire des Matières pour Eurodifroid ERI

  • Page 1 GAMME INDUSTRIE INDUSTRY LINE REFROIDISSEURS D'EAU WATER CHILLERS R F C MANUEL D’INSTALLATION ET D’UTILISATION INSTALLATION AND OPERATING INSTRUCTIONS V4.0 MAJ LE 07/11/2012...
  • Page 2 GARANTIE CONSTRUCTEUR Nos fabrications bénéficient d’une garantie de 18 mois maximum contre tout vice de fabrication à partir de la date de livraison. Cette garantie ne s’applique que si le matériel est installé conformément à nos prescriptions ou règles de l’art, et s’il est utilisé dans les conditions normales. Cette garantie se limite au remplacement de la pièce reconnue défectueuse après examen de notre service technique ou à...
  • Page 3 Dans le cas d’un refroidisseur intégré (type ERI), certaines configurations (le plus souvent en triphasé), nécessitent un câblage par composant. L’utilisateur devra se connecter sur le bornier prévu à cet effet. Les principes de base vus ci- dessus devront être respectés.
  • Page 4 EURODIFROID commercialise des liquides de refroidissement glycolés prêts à l’emploi (LAC). N’hésitez pas à contacter notre service technique pour une étude de votre application. La non utilisation de ce liquide antigel est à l’initiative de l’utilisateur. Remarque : l’ajout d’antigel peut réduire les performances.
  • Page 5 DEPANNAGE MARCHE A SUIVRE Le dépannage d’un groupe frigorifique nécessite l’intervention d’un personnel spécialisé. Toutefois,dans la mesure où le refroidisseur aurait une avarie ne nécessitant pas l’accès au circuit frigorifique, le dépannage par un service maintenance en mécanique / électricité peut s’avérer suffisant. Dans tous les cas, nous vous conseillons de contacter notre société...
  • Page 6 CONSTRUCTOR'S GUARANTEE Our products are covered by a guarantee of maximum 18 months against manufacturing fault, starting from the delivery date. This guarantee is only valid if the equipment is installed in compliance with instructions or standard practice, and used under normal conditions. This guarantee is limited to the replacement of parts recognised as faulty after examination by our technical department, or repair in our workshop.
  • Page 7 For an integrated chiller (ERI type), some configurations (usually three-phase) require wiring of each component. The user must make the connections on the appropriate terminal block. The above principles must be observed.
  • Page 8 STARTING UP WARNING : THE UNIT MUST NOT BE STARTED UP .BEFORE BEING LEFT TO STAND, WITHOUT HANDLING, FOR AT LEAST 3 HOURS  CIRCUIT FILLING A/ CHILLER WITHOUT PUMP (TYPE D) Usually, the circuit is already fitted with a pump when the chiller is installed. Check that pressure flow rate of the pump is in accordance with the chiller data on the chiller’s plate.
  • Page 9 REPAIRS PROCEDURE Repair a refrigerating unit must be carried out by specialised technicians. However, provided that the problem on the cooler does not require access to the cooling circuit, repair can be undertaken by a mechanical/electrical maintenance team. For any problem, we advise you to contact us for a list of approved after sales service companies. TROUBLE-SHOOTING CHECK AND REMEDY FAULT OBSERVED...
  • Page 10 Water Inlet Remplissage F 1/2" Filling Voyant d'eau Level Indicator Sortie d'eau Water outlet F 1/2" Sortie d'air Air outlet ERI 07 à 20T Sortie d'eau ERI07 ERI12 ERI20 Water outlet Ø O A(mm) Entrée d'eau Water Inlet B(mm) Ø I...
  • Page 11 SCHEMA HYDRAULIQUE ET FRIGORIFIQUE HYDRAULIC AND FRIGORIFIC DIAGRAMS ERI02 ERI 07 - 20 LEGENDE (COMMUNE AUX DEUX SCHEMAS) / LEGEND (AVAILABLE FOR BOTH DIAGRAMS) Compresseur Compressor Pressostat Basse Pression Low pressure pressostat Thermostat de régulation Regulation thermostat Thermostat basse et/ou haute température Temperature low and/or high thermostat Condenseur à...
  • Page 12 SCHEMAS ELECTRIQUES ELECTRICAL DIAGRAMS ERI 02 – 07 – 12 - 20 PROTECTION ERI 02 4A aM ERI 07 6/8A aM ERI 12 ERI 20 8/10A aM RVT 05 0.25A 4A aM RVT 05 HP 1.1A...
  • Page 13 COURBE DE POMPE GAMME RFC / RFI PUMP CURVE RFC / RFI LINE COURBE DE POMPE ERI 02 à ERI 20T ERI 12 - 20 ERI 02 - 07...
  • Page 14 SERVICE CLIENT / AFTER SALES SERVICE Ligne directe / Direct line: + 33 (0) 241 766 706 Standard : + 33 (0) 241 762 840 : eurodifroid.service@eurodifroid.fr SIEGE SOCIAL ET SERVICES TECHNIQUES / FACTORY ZI SUZEROLLES – 49140 SEICHES SUR LE LOIR Tél : +33 (0)2 41 76 28 40 –...