Fichier d'exemple modem_m1.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP modem_m1
#
# FUNCTIONS: Modem configuration file specifically for IBM 7857–017 modem with
# Auto–Reliable feature. This feature must be turned off for Catcher calls.
# This example uses the AT&F reset command to choose the factory defaults.
#
# To allow dial commands for digital pagers, it is necessary to reduce
# the number of characters in the dial command. Each comma (delay) has
# been set to 6 seconds (S8=6) for that reason.
#
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials – Property of IBM
#
# US Government Users Restricted Rights – Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
ICDelay 1
DefaultTO 10
CallDelay 120
#
# %N Call–Out phone number %R Return phone number
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout: send "AT&F*E0E0\r"
ignore "0\r" or "OK\r\n" timeout 2
send "AT#F0*Q2S8=6\r"
expect "0\r" or "OK\r\n" timeout 2
send "ATV0X0S0=0\r"
expect "0\r" or "OK\r\n" timeout 2
done
connect: send "ATDT%N\r"
expect "1\r" busy "7\r" timeout 60
done
retry:
send "A/"
expect "1\r" busy "7\r" timeout 60
done
disconnect:
delay 2
send "+++"
delay 2
send "ATH0\r"
ignore "0\r" or "OK\r" timeout 2
send "ATE0Q1\r"
ignore "0\r" timeout 1
done
C-18
ESCALA PL 220T et PL 220R Guide de l'utilisateur
# Reset to factory defaults.
# *E0=data compression disabled
# E0=echo disabled
# Ignore modem response.
# Trellis modulation disabled
# Retrain with adaptive rate
# Set ,=6second
# Confirm commands successful
# Numeric response code
# AT compatible messages
#
# Auto–Answer disabled
# Confirm commands successful.
# Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.
#
Repeat the previous command.
# Expect a connection response.
# Separate from previous data.
# Assure command mode.
# Allow mode switching delay.
# Set modem switch–hook down
# (i.e., hang up).
# Ignore modem response.
# Initialize modem: Echo OFF,