Long Term Storage; Battery Replacement On Remote; Service And Storage; Infrequent Service - etrailer P03616 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
To avoid electric shock:
ALWAYS connect the positive (+) battery cable
(red boot) first when connecting battery cables.
ALWAYS disconnect the negative (-) battery
cable (black boot) first when disconnecting
battery cables.
NEVER connect the negative (-) battery cable
(black boot) to the positive (+) post on the
battery.
NEVER connect the positive (+) battery cable
(red boot) to the negative (-) post on the battery.
NEVER touch both battery posts simultaneously.
NEVER place a metal tool across both battery
posts.
ALWAYS use insulated or nonconducting tools
when installing the battery.

Battery Replacement On Remote

1. Loosening and remove cover screws.
2. Remove the cover.
3. Remove the depleted batteries and insert
two new CR2016 lithium batteries with the
"+" terminal facing up.
4. Close the remote cover and tight the screws.

SERVICE AND STORAGE

Infrequent Service

If the unit is used infrequently, difficult starting
may result. To eliminate hard starting, follow
these instructions:
1. Run the generator at least 30 minutes every
month.
2. Run the generator, then close the fuel shut-off
valve and allow the unit to run until the engine
stops.
3. Move the engine switch to the "OFF" position.
English
Lithium Battery

Long Term Storage

It is important to prevent gum deposits from forming
in essential fuel system parts such as the carburetor,
fuel hoses or tank during storage. Also, experience
indicates that alcohol-blended fuels (called gasohol,
ethanol or methanol) can attract moisture, which leads
to separation and formation of acids during storage.
Acidic gas can damage the fuel system of an engine
while in storage.
When the generator set is not being operated, or
is being stored for more than one month, follow
these instructions to avoid engine problems:
1-ADD a properly formulated commercially FUEL
STABILIZER to the tank if it is not already added.
2-Operate the engine for 5-10 minutes to circulate
treated fuel into fuel lines and carburetor before
shutdown.
3- After engine cools down, remove all gasoline
from the fuel tank. Use a commercially available,
non-conductive vacuum siphon.
DANGER
Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool.
Do not smoke.
4-FUEL STARVATION: Start and run the generator
until it stops from lack of fuel. This will dry out all
remaining fuel in tank, fuel lines and carburetor.
5-Allow the unit to cool entirely before cleaning
and storage.
6-Change oil with recommended grade oil.
7-Remove spark plug and pour about one teaspoon
of engine oil through the spark plug hole, then pull
the recoil starter several times to distribute the oil for
lubricating the cylinder. Reattach the spark plug.
Pull recoil slowly until resistance is felt. This will
close the valves so moisture cannot enter engine
cylinder. Gently release recoil starter.
Page 27
Customer Service: 1-844-347-6261

Publicité

Table des Matières
loading

Table des Matières