Leveling Legs
Adjustable legs at the front and rear corners of the unit should
be set so the unit is firmly positioned on the floor and level from
side to side and front to back. The overall height of your Marvel
refrigerator, depending on the model, may be adjusted from
241/8" (61.3cm) or 333/4" (85.7cm) with the leveling legs turned in,
and up to 251/8" (63.8cm) or 343/4" (88.3cm) with the leveling legs
extended.
To adjust the leveling legs, place the refrigerator on a solid
surface and protect the floor beneath the legs to avoid scratch-
ing the floor. With the assistance of another person, lean the
refrigerator back to access the front leveling legs. Raise or lower
the legs to the required dimension by turning the legs. Repeat
this process for the rear by tilting the refrigerator forward using
caution to prevent the door from opening. On a level surface
check the refrigerator for levelness and adjust accordingly.
The front grille screws may be loosened and the front grille
adjusted to the desired height. When adjustment is complete
tighten the two front grille screws. (See Figure 3).
Figure 3
INSTALLING YOUR ICE MACHINE
Front Grille
Front grille screw
Do not splash or spray water from a hose on the ice ma-
chine! Doing so may cause an electrical shock, which may
result in severe injury or death.
This unit should not, under any circumstances, be installed
to an un-grounded electrical supply.

Electrical Connection

A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that
has a three-pronged, grounded plug. It must be plugged into a
mating grounding type receptacle in accordance with the Na-
tional Electrical Code and applicable local codes and ordinances
(see Figure 4). If the circuit does not have a grounding type re-
ceptacle, it is the responsibility and obligation of the customer to
provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.
ous and cause deficient operation. The wall receptacle should
be located near the product and be a polarized type with
adequate ground protection. The product must be installed to
your local building codes and ordinances.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance
tripping which will cause the unit to shut down. GFCI's are gener-
ally not used on circuits with power equipment that must run
unattended for long periods of time, unless required to meet
local building codes and ordinances.
5
Electrical Extension cords should
not be used. They can be hazard-
Figure 4