DELTACALOR PIANO Notice D'utilisation Et D'installation page 47

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Key lock
It is possible to lock the buttons of the device to avoid inadvertent modificationsof the
settings.
Press together the [PROG] buttons for 3 seconds to lock all the buttons except the [On/
Stand-by] button. The key-lock icon is activated on the display. To
The key-lock icon is activated on the display
To unlock the buttons press again together the [PROG] buttons for 3 seconds.
The key-lock icon disappears on the display
Open Window Detection function
The "Open Window Detection" function enables detecting of an open window by sensing a sud-
den decrease of the temperature in the room. In such a case, the device deactivates the heating
element for a maximum of 30 minutes or until an increase of the room temperature reveals that
the window has been closed.
To activate this function:
Enter into "Stand-by" mode.
Press the [+] button for 3 seconds.
Press the [+] button to activate / deactivate the function
Press the [Prog] button to commit and return into "Stand-by" mode.
When this function is enabled, the "Open Window" icon
When the device detects that the window is potentially opened, the "Open Window"
icon
starts blinking
When the function is disabled the "Open Window" icon is not shown on the display.
NOTE - The device could fail in detecting an opened window e.g. if the thermostat is located on
an isolated area of the room and far from air currents or if the thermostat is placed close to an
external heating source, or if the temperature variation in the room is too slow.
NOTE - When the symbol
is on, the heating element is active.
[ 47 ]
ON/Stand by
on the display is lit.