1-9 Programming
T. °C standby
1-9 Programming
T. °C standby
5.

MENU 2, DATA DISPLAY.

MENU 1 allows to set all data related to the operation of the boiler while MENU 2 displays the values of
operation, extractor's rotation Speedy, extraction air level, etc.
To enter MENU 2 follow those stops: Press MENU (
increase (
V
) and the following is displayed:
MENU 2
Visualise data
2-0 Gas
Temperat.
2-1 Internal CPU
Temperat.
2-2 NTC gauge
temper.
2-3 Vaccum intak.
pressure
2-4 Exhaust fan
speed
2-5 Total time
running
2-6 Number of
starts
Press MENU (
_ _ °C
This menu aims at programming the water temperature at which the boiler
shall turn off; this value is set at manufacture at 78°C. If, due to the installation
conditions, the temperature would increase more rapidly, and to avoid
activation of the security thermostat, the boiler will turn off. When the gas
78 °C
outlet temperature decreases respectively to 80°C and 40°C, it will start again.
At point 1-9, the parameter that can be set, if necessary, is the activation
temperature of the "stand-by".
If you press MENU (
As indicated, the gas outlet temperature is displayed in real time. Press
increase (
20°C
The internal temperature of the electronic CPU plate is displayed; its
operation temperature is between 10 °C and 55 °C. Press increase (
25°C
switch to next step.
The temperature of the probe which controls the activation of the
recirculation pump or the convector speed is displayed on real time basis.
20°C
Press increase (
The real value of air depression generated by the boiler in air input pipe is
displayed. If this value was not suitable, the boiler would indicate a failure
on the main screen, the value varies depending on the model. Ask your
0.00mB
local distributor for correct values. Press increase (
Display of the tension percentage at which the extractor motor is running.
Press increase (
00 %
Total number of hours of operation since first start-up. This is useful to
know when maintenance shall be done. The number of hours varies
depending on the model. Ask your local distributor. Press increase (
000000 h.
go to next step. This is important for maintenance and guarantee.
Number of start-ups since first operation. This is useful to know the lifetime
of the starting resistance (electrode). Press increase (
000000
step.
) to reach said menu.
Z
Z)
and you reach MENU 1-User programme, press
you enter data display:
Z)
V
) to go to next step.
V
) to go to next step.
V
) to go to next step.
225
) to
V
) to go to next step.
V
) to
V
V
) to go to next