Suction line - PVC cristal
Water dynamic pressure must
be between 2 and 6 bar.
WATER
1/2''
CLEANING or REPLACEMENT of filter gasket
1_Unscrew the nut of the stainless hose.
2_Clean or replace the filter gasket.
3_Reassemble the filter gasket, repect orientation
Foam unit PROFOAM doesn't suck product.
1°_ Check the pressure of the w ater system (minimum : 2 bars, maximum : 6 bars)
2°_ Check that the filter gasket is not dirty or scaled. (clean or replace)
3°_ Check that the yellow filter of the suction line is submerged in the product,
and the hose is not pinched, folded, or closed.
4°_ Verify that the tip is not clogged. (clean or replace)
5°_Check that the yellow filter of the suction line is not dirty. (clean or replace)
6°_ Check that the spray handle is not dirty or calcified. (clean or replace)
The can fills up w ith w ater
7°_ Verify that the check valve is not dirty or calcified. (clean or replace)
Foam unit PROFOAM – Troubles
3/4''
MAINTENANCE
Air diffuser

Compressed air

regulator.
Air valve with quick
connector
Blue hose
COMPRESSED AIR
Air pressure must be
between 2 and 6 bar with a
flow rate of 100 litres/mn.
CLEANING of the non-return valve
Ceramical ball
GB
S/ST wand
Blue rubber
handle.
O ring