Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking
water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 38)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance (see page 43)
The check valves must be checked regularly according
to DIN EN 1717 in accordance with national or
regional regulations (at least once a year).
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 33)
English
Dimensions (see page 32)
Flow diagram (see page 32)
Spare parts (see page 39)
Special accessories (order as an extra)
extension #43333000 (see page 44)
Cleaning (see page 40)
Operation (see page 42)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate (see page 42)
65°C
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Set hot water limiter