Meter User's Manual
Installing the Meter
Step 1
Remove power from the electrical panel.
Step 2
Remove the cover panel so you can access the wires.
Step 3
Ensure that there is a short-circuit protection (breaker or fuse) before
the Meter no larger than 230 VAC 65 A.
Step 4
Put the Meter on the DIN rail of the home distribution box and ensure
the hook is locked properly (IMAGE 5).
Connect the SBUS to any other device that is part of the installation.
The left SBUS of the Meter must be connected to the Bridge-Box (REF
CMB-01.1011) or other devices connected to the Bridge-Box. The right
SBUS can be connected to other devices of the family. An SBUS is con-
nected in one of the 2 ways:
If this Meter is at the end of the chain of tiko devices, close the remain-
ing openings using Cover B and Cover C (IMAGE 7).
Step 5
Prepare the cables. Refer to
Specifications on page 8 for supported ratings and cable diameters.
Remove the insulation at the end of the cable and apply an insulated or
uninsulated bootlace ferrule (IMAGE 8):
tiko Energy Solutions AG
Installation by person with electronical expertise and trained on this
product only!
Do not install the device unless you have removed the main power sup-
ply (main breaker or fuses)!
Using the SBUS interconnector: Plug the SBUS connector in
one of the devices and slide the Meter along the DIN rail to-
wards it (IMAGE 6). Use the Clip A to prevent the SBUS from
being disconnected (IMAGE 7).
Using the SBUS cable: Connect the Meter to the other device
using the provided SBUS cable. Warning: SBUS cables shall not
be close to power cables. Minimum clearance is 10 mm.
English
Installation
5 / 44
IM-0007-0003 Rev. 6