Electrical connection

The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is
about 1W for 5 gas burner version or 2W for 6 gas burners version.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong)
grounding plug for your protection against shock hazard and should be plugged directly into a
properly grounded receptable. Do not cut or remove the grounding prong from this plug.

Wiring diagrams

For hotplate model A see Fig. 13.
For hotplate model B, C see Fig. 14.
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in
conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be
installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described
in fig. 5.
- CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS:
To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 8) using an adjustable spanner of 7 mm and change the
nozzles with those designed for the new gas supply according to the information given in TABLE A shown
below.
TABLE A: Adapting to different types of gas
Drop-in cooktop with 5 workyop burners model B3H0..(A or Q)8X(2 or 5)D
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L
Rear R
Rapid
Front L
Centre Inner
Dual
burner
Centre Outer
Drop-in cooktop with 6 workyop burners model B3K0..(Q or U)8X(2 or 5)
Burner
Position
Auxiliary
Front R
Semi-Rapid
Rear L & C
Front C
Rapid
Rear R
Centre Inner
Dual
burner
Centre Outer
CAUTION: save the orifices removed from the appliance for future use
Inj. size
Gas
1/100mm
Type
92
NG
56
LP(Propane)
117
NG
73
LP(Propane)
155
NG
98
LP(Propane)
80
NG
50
LP(Propane)
N°2 x 130
NG
N°2 x 83
LP(Propane)
Inj. size
Gas
1/100mm
Type
0,92
NG
0,56
LP(Propane)
1,17
NG
0,73
LP(Propane)
1,55
NG
0,98
LP(Propane)
0,80
NG
0,50
LP(Propane)
N°2 x 1,30
NG
N°2 x 0,83
LP(Propane)
Wiring diagram description
1. Cable terminal
2. Ignition switch
3. Spark generator
4. Ignition spark
L. Black
N. White
T. Green (earth)
Pressure
Max Rate
[i.w.c.]
[BTU/h]
4"
3750
1098
11"
3750
1098
4"
6000
1759
11"
6300
1845
4"
10400
2046
11"
11400
3339
4"
11"
NG 17000
4980
4"
LP
18800
5507
11"
Pressure
Max Rate
[i.w.c.]
[BTU/h]
4"
3750
1098
11"
3750
1098
4"
6000
1759
11"
6300
1845
4"
10400
2046
11"
11400
3339
4"
11"
NG 17000
4980
4"
LP
18800
5507
11"
5
Min Rate
[W]
[BTU/h]
[W]
900
264
900
264
1500
439
1500
439
2500
732
2500
732
900
264
Min Rate
[W]
[BTU/h]
[W]
900
264
900
264
1500
429
1500
439
2500
732
2500
732
900
264
By-pass size
[1/100mm]
Regulated
29
Regulated
36
Regulated
47
Regulated
29
Regulated
65
By-pass size
[1/100mm]
Regulated
29
Regulated
36
Regulated
47
Regulated
29
Regulated
65

Publicité