Repair And Replacement - Ruffneck ProVector CX1 Serie Manuel Du Propriétaire

Masquer les pouces Voir aussi pour ProVector CX1 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnect the power supply before installation of the heater. Lock the switch in the "OFF" (open)
position and/or tag the switch to prevent unexpected power application. Heater surfaces may be hot.
FINNED TUBE/ELEMENT ASSEMBLY
A complete finned tube assembly is available from the factory. Refer to Parts Diagram for item numbers.
1. Remove the front cabinet panel (Item #1).
2. Remove convector enclosure's cover and disconnect wires.
3. De-couple two unions (Item #9) connecting convector enclosure and finned tube extension (Item #7).
4. Remove 3/4" NPT plug (Item #11) from element conduit (Item #10) and then pull out wire connector and
disconnect the wires.
5. De-couple remaining two unions and remove element conduit.
6. Remove union halves and lock-nut (Item #8) from ends of each finned tube requiring replacement and set
aside for re-use on new factory supplied finned/element assemblies.
7. Remove bolts from lower tabs of wall mount brackets (Item #6), remove heater from wall mount brackets,
and loosen the bolts from the finned tube bracket (Item #5).
8. Remove the damaged finned tube/element assemblies and install replacements.
9. Re-assemble heater using the reverse order of the preceding instructions.
Important: All threaded connections must be wrench tight with a minimum of 5 turns engagement.
CABINET PANELS AND BRACKETS
Replacement cabinet panels and brackets are available from the factory.
NOTE: For purposes of safety and convenience, all repairs and maintenance must be done with factory
authorized parts and materials.
Cabinet Length
Net Weight
Shipping Weight
Enclosures
Mounting Brackets
Heating Elements
Cabinet Material
Temperature Code Rating
Hazardous Locations
Without Built-in T'Stat*
Temperature Limitations
*Hazardous location ratings are dependant on the junction box used.
Please consult a customer service representative or the unit data plate for actual location ratings.

REPAIR AND REPLACEMENT

SPECIFICATIONS
0.75 - 2.69 & 3.6 (T2A)
in (mm)
lbs (kg)
lbs (kg)
Defender ® housing is cast aluminum with bolt on cover. Groups IIB
x-Max ® housing is extruded aluminum with two screwed on covers. The x-Max ®
housing offers IP55 moisture ingress protection. Groups IIC. For dry indoor use
only. Do not immerse in water. Do not store or use in areas exposed to rain or
snow.
Two 14 Ga. (0.075 in)(1.90mm) galvanized steel.
Two Incoloy ® sheathed elements.
14 Ga. steel. Rear panel is galvanized. Front and side panels are baked green-
grey epoxy powder coated with five-stage pretreatment, including iron phosphate.
T2A 536°F (280°C), T3 392°F (200°C)
Class I, Div. 1 & 2, Groups A, B, C, & D; Class I, Zones 1 & 2, Groups IIA, IIB & IIC
Class I, Div. 1 & 2, Groups A, B, C & D; Class I, Zones 1 & 2, Groups IIA, IIB & IIC
With Built-in T'Stat*
Operational: -49°F to 104°F (-45°C to 40°C)
Storage: -49°F to 176°F (-45°C to 80°C)
WARNING
3.01 - 3.59, 3.6 (T3)
31.3 (796)
55.3 (25.1)
65 (30)
– 6 –
Nominal kW
4.76, 5.28 - 7.6
& 4.8
49.4 (1256)
80.7 (36.6)
95 (44)
59.5 (1511)
92.8 (42.1)
105 (47.6)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Provector cx1-120160-012-t3Provector cx1-120160-018-t3Provector cx1-208160-012-t3Provector cx1-208160-018-t3Provector cx1-208160-036-t3Provector cx1-208160-048-t2a ... Afficher tout

Table des Matières