Télécharger Imprimer la page

Maintenance; Every (2) Months; Vacation And Long-Term Storage - Bruno VPL-3200B Serie Guide De L'utilisateur

Plateforme élévatrice verticale

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE

EVERY (12) MONTHS (more frequently if the lift is used under strenuous conditions),
have the lift undergo a complete inspection by an authorized Bruno dealer and have this
dealer make any necessary repairs/replacements. Having the VPL-3200B serviced by
someone other than an authorized Bruno dealer will render your warranty null
and void.
1. Check the suspension/drive system:
• belts, including belt tension
• belt pulleys and shafts, including keys
• motor
• bearing (see Note 1)
2. Verify that the platform stops within 1/2" (13 mm) of the landing.
3. Inspect the platform controls and the call/send controls.
4. Inspect the wiring and connectors (see Note 2).
5. Verify general cleanliness of the unit. (It is not uncommon to remove mouse nests.)
NOTE 1: Bruno uses a special grease for better performance over a wider temperature range,
especially in colder environments. Please use Mobil AVIATION GREASE SHC 100 (Bruno
part no. LUB-00114).
NOTE 2: To help protect connector pins from moisture, apply dielectric grease to connectors
exposed to the elements (ex. rain, snow).

EVERY (2) MONTHS

1. Units with electronic door interlock: verify that the platform does not move when any door is not closed
and locked.
2. Units with GAL door interlock: verify that the platform does not move more than 2" (51 mm) in
relation to the landing.
3. Verify that the safety pans (under the platform) are working properly.
NOTE: Do not work under the platform when testing operation.
NOTE: Please reference ILS-01444 (Maintenance Control Plan for Vertical Platform Lifts) for units
that require ASME A18.1 - 2017 and newer compliance.

VACATION AND LONG-TERM STORAGE

©Bruno Independent Living Aids, Inc.
MAINTENANCE and LONG-TERM STORAGE
• Acme screw and drive nuts
• Acme screw lubrication (see Note 1)
• pads and rollers
circuito
interruptor
10
®
During extended periods of non-use, keep
the VPL-3200B plugged into a live, properly-
grounded AC outlet and place the circuit
breaker switch in the OFF position.
VPL-3200B OPERATOR 08-15-2019

Publicité

loading

Ce manuel est également adapté pour:

Vpl-3210bVpl-3212bVpl-3214b