Les langues disponibles

If none of the fields are pressed for 10 s the menu automatically returns to normal
functioning.
If the code is entered incorrectly, the programme automatically exits the
introductory menu.
When the code is entered correctly, the first parameter appears. The number on
the right consecutive number of the parameter and the number on the left is its
value.
The first parameter :00 is the version of the programme code that is purely of
informative nature.
By pressing the right number (the CLOCK field on Figure 6) the next parameter is
displayed.
Installation menu: CODE 1166:
After the installation menu code is entered correctly, the following parameters can be
accessed:
:00
programme code version (informative parameter)
o
:21
setting the speed of fan
o
:27
setting low-temperature mode
o
Setting the speed of the fan (parameter :21)
When the parameter (:21) is selected, press (+) or (-) to set the desired fan speed (40-
100%). On the left side (field 5) the numeric value of the setting is displayed. When the
desired speed of the fan is set, it is stored after a short delay or after pressing field no. 4.
Setting the low-temperature mode of operation of the heat pump (parameter :27)
When parameter :27 is selected, press (+) or (-) to determine the temperature mode of
operation of the heat pump, which depends on the version of the heat pump.
temperature mode can only be set if the heat pump version allows it!****
side (TEMP field) the set mode is displayed:
Yes – heat pump version TC ZNT, heat pump operation mode (up to -7°C), the system
includes a 4-way valve
No – heat pump version TC Z, heat pump operation mode 7°C, the system does not
include a 4-way valve
Note:
****The low-temperature mode of operation of the heat pump is a setting that the installer can only set
if the version of the heat pump is appropriate. When replacing the electronic module, the mode of
operation must be selected in such a way that it suits the version of the heat pump!