Filter Pressure Is Below The Pressure Indicated By The Blue Hand; Filter Pressure Rises Out Of The Green Zone - BWT RTM CT T-500 Notice D'installation Et Conseils D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.1.1 Filter pressure is below the pressure indicated by the blue hand
Clean the pre-filter basket and the skimmers:
Stop the pump,
Put the 6-way multiport valve to "CLOSED",
Close the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
Open the pre-filter and take out the basket,
Using a jet of water remove any debris,
Put the basket back,
Replace the lid of the pre-ilter making sure that the seal is correctly positioned and that there is enough
water to prime the pump,
Clean out the skimmers.
Put the 6-way multiport valve to "FILTRATION",
Open the suction valves A, B, C, D (skimmers, main drain) and the return fitting valve E,
Restart the pump,
Purge air from the filter.
This operation should be carried out each time the pool is vacuumed using a brush on a suction line, and
at least once a week.
4.1.2 Filter pressure rises out of the green zone
Back wash the filter
Stop the filter,
Check the pre-filter for debris. (If there is a build-up of dirt clean it out as described above),
Put the 6-way multiport valve to the "WASH" position,
Open the 1/4 turn valve (F) on the outflow pipe,
Turn the motor on,
Monitor the water colour through the turbidity sight glass on the 6-way multiport valve.
CAUTION !
Cleaning will start after a few seconds. (The water becomes very cloudy).
As soon as the water in the turbidity sight glass becomes clear, stop the pump,
Put the 6-way multiport valve to the "RINSE" position,
Turn the pump on for about 20 to 30 seconds. The purpose of this step is to evacuate any remaining
impurities and settle the sand,
Stop the pump,
Put the 6-way multiport valve to the "FILTRATION" position,
Restart the pump,
Close the 1/4 turn valve (F) on the waste line.
After back washing, the black hand on the pressure gauge should be realigned with the blue hand, that is
the pressure reading should return to the nominal pressure.
In the event that the pressure indicated by the pressure gauge does not drop after back washing
the filter once (or even twice) contact your installer.
20/36