Operating Precautions - Enerco HeatStar HS85FAV Instructions D'utilisation Et Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NEVER
NEVER LEA
NEVER LEA
SPECIFICATIONS
Model:
55FAV
Rating:
30,000 - 55,000 Btu/Hr
(8.8 - 16.1 kW)
Fuel Consumption:
1.4-2.5 #/hr
(.64-1.1 kg/hr)
Fuel Orifice Port No.:
18
Fuel Orifice Port Size:
0.0196"
(0.50mm)
Heated Air Output:
300 cfm
(8.49 cmm)
Average Air Temp. Rise:
200°F (111°C)

OPERATING PRECAUTIONS

This is a propane, direct-fired, forced air heater. It's intended use
is primarily temporary heating of buildings under construction,
alteration or repair.
Propane is heavier than air. If propane leaks from a connection or
fitting, it sinks to the floor, collecting there with the surrounding
air, forming a potentially explosive mixture. Obviously, propane
leaks should be avoided, so set up the propane supply with
utmost care. Read enclosed Odor Fade and Propane Sheet for
additional information about detecting propane leaks. Leak check
new connections or reconnections with a soap and water solution
and follow all connection instructions herein. Also, ask your
propane dealer for advice on the propane application and supply
installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction
heater in accordance with ANSI Z83.7/CGA 2.14. Check with
your local fire safety authority if you have any questions about
your applications. Other standards govern the use of fuel gases
and heat producing products in specific applications. Your local
authority can advise you about these.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to 100
percent combustion efficiency, it still produces small amounts of
carbon monoxide. Carbon monoxide (called CO) is toxic. We can
tolerate small amounts but not a lot. CO can build up in a heated
space and failure to provide adequate ventilation could result in
death. The symptoms of inadequate ventilation are:
• headache
• dizziness
• burning eyes and nose
• nausea
• dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating
instructions.
Forced Air means that a blower or fan pushes the air through the
heater. Proper combustion depends upon this air flow; therefore,
the heater must not be revised, modified or operated with
parts removed or missing. Likewise, safety systems must not be
circumvented or modified in order to operate the heater.
LEAVE THE HEA
VE THE
VE THE HEA
HEATER UNA
TER
TER UNA
60FAV
30,000 - 60,000 Btu/Hr
(8.8 - 17.6 kW)
1.4 - 2.8 #/hr
(0.64 - 1.28 kg/hr)
18
0.0247"
(0.52mm)
300 cfm
(8.49 cmm)
200°F (111°C)
Forced Air Propane Construction Heater
UNATTENDED WHILE BURNING!
TTENDED WHILE BURNING!
TTENDED WHILE BURNING!
85FAV
50,000 - 85,000 Btu/Hr
(14.6 – 25.0 kW)
2.3 – 3.9 #/hr
(1.04 – 1.77 kg/hr)
18
0.0236"
(0.60mm)
300 cfm
(8.49 cmm)
200°F (1 1 1°C)
When the heater is to be operated in the presence of other people
the user is responsible for properly acquainting those present
with the safety precautions and instructions, and of the hazards
involved.
3
Operating Instructions and Owner's Manual
125FAV
75,000 - 125,000 Btu/Hr
(21.9 – 36.6 kW)
3.5 – 5.8 #/hr
(1.59 – 2.63 kg/hr)
18
0.0295"
(0.75mm)
350 cfm
(9.91 cmm)
400°F (232°C)