Troubleshooting

SYMPTOM
Tool will not turn ON
when ON/OFF button on
display panel is pressed.
Tool will not run when
trigger is depressed.
Green light flashes.
Tool turns OFF
either when trigger is
de pressed or in the
middle of a press cycle.
Red LED glows.
Yellow LED blinks
repeatedly as long as
tool is turned ON and
tool functions properly.
Yellow LED glows con-
tinuously and tool will
not begin press cycle
when trigger switch is
depressed.
Red LED blinks repeated-
ly and tool will not begin
press cycle when trigger
switch is depressed.
Yellow LED glows when
tool is turned ON.
Jaws are locked onto
fitting.
The pressed connections
produced are not com-
plete.
POSSIBLE REASONS
Battery is completely discharged or battery has
failed.
Battery not properly inserted into handle of tool.
Battery is too low.
Tool or battery is too cold or too hot.
Scheduled maintenance/recalibration is required
after 30,000 presses.
Scheduled maintenance/recalibration is manda-
tory after 32,000 presses. Tool is "locked" and
will not function until tool is serviced.
Attachment mounting pin not fully closed.
Tool malfunction detected.
Press was not successfully completed.
Used wrong jaws for the tube size or material.
The tool was not square to the tube.
Jaw contour was not aligned with the fitting contour.
Tool is in need of repair.
RP 210 Press Tool
SOLUTION
Insert fully charged battery/recharge dead battery.
Check to assure battery is fully inserted.
Insert fully charged battery/recharge dead battery.
Bring tool and battery to correct operating range
between 0°F (-20°C) to 140°F (60°C) by allowing
the tool to sit in a conditioned room. If using tool
in cold temperatures, refer to Cold Weather
Operation Section of this manual.
NOTE! Fitting must be repressed if tool stops
in the middle of a press cycle. Failure
to do so may result in a leaking fitting.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Authorized Service
outlet.
Contact Ridge Tool Technical Service Department
at (800) 519-3456 for nearest Authorized Service
outlet.
Insert attachment mounting pin to the fully closed
position.
Remove and reinsert fully charged battery. Be sure
to repress fitting. If LED's continue to glow, contact
Ridge Tool Technical Service Depart ment at (800)
519-3456 for nearest Author ized Service outlet.
Push pressure release valve to remove jaws from fit-
ting. Inspect and repress fitting.
Install the correct jaws.
Redo the joint with new fitting and new tube.
Make sure that the tool is square to the tube.
Redo the joint with new tube and new fitting.
Make sure the jaw contour is aligned with the
fitting contour.
Contact Ridge Tool Technical Service De partment
at (800) 519-3456 for nearest Author ized Service
outlet.