Kokido K2O K880BX/EU Manuel D'utilisation page 25

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Running in different period of time
The controller contains real time clock, and can time accurately. In "Econ Mode", the controller will
ensure that whether need to heat according to water temperature, otherwise the current time is in or
not in the setting period of time, if it is not in the setting period of time, then the controller will not heat
whether the water temperature is high or low.
The controller can be set 3 heat periods of time at most, if you don't need some periods of time, you
can set the starting time and ending time which you don't need as "OFF".
In addition, if the ending time is earlier than starting time, the controller considers this ending time is
next day. For example, the period of time is "22:00"to"03:30", the controller considers it as 22:00 at
night to 03:30 next day.
Probation time
A probation time can be set (F87), the controller can add up the running time after power is on, if the
accumulative running time is over the probation time, the controller will stop and display the alarm
code A99, if you want to eliminate the limit of probation time, set the F87 to "OFF", also you can use
the F86 to clear the accumulative running time, and you can try to use it again. The parameter F85
can be used to examine the accumulative running time of the controller (hour).
Password
In order to prevent irrespective persons from changing the parameters, you can set a password (F80),
and if you have set a password, the controller will hint you to enter the password after you press the
key "M" for 5 seconds, you must enter the correct password, and then you can set the parameters. If
you don't need the password, you can set F80 to "OFF".
Notice that you must remember the password, and if you forget the password, you can not
enter the set state.
The heat pump will take several days to reach the requested temperature. The exact
length of time will vary depending on pool size, ambient temperature and wind speed.