CURRENT SENSOR LEVEL

To modify the current sensor level procede as follow:
1. Press and keep pressed the key P1 for 5sec (courtesy light
ON) and at the same time transmit with the key 1 of the
transmitter (the transmission must last 3 sec).
2. When the courtesy light switch off, stop the transmission
and release P1 key.
3. After 2 sec. the courtesy light visualizes the setted level with
the relative number of flashes. SEE CHART.
4. The courtesy light switch off for 2 sec. Then it goes on again
for 5 sec. waiting for a transmission.
5. Transmit (within 5sec) with the ideal key according to the
CHART.
6. The courtesy light switch off for 2 sec and therefore it
visualizes the new level setted with the relative number of
flashes. SEE CHART.
TX KEY
FLASHING N° DESCRIPTION
Key 1
1
Key 2
2
Key 3
3
Key 4
4
To correct any one of the parameters, restart from point 1.

FUNCTIONING LOGIC

To modify the functioning logic procede as follow:
WARNING: In case the photocell is connected the AUTOMATIC
logic can be selected; in case the photocell is not connected
it will work with the STEP BY STEP logic only.
The photocell TX must be connected to the proper terminals
for the check test 10 and 5.
1. Press and keep pressed the key P1 for 5sec (courtesy light
ON) and at the same time transmit with the key 2 of the
transmitter (the transmission must last 3 sec).
2. When the courtesy light switch off, stop the transmission
and release P1 key.
3. After 2 sec. the courtesy light visualizes the setted level with
the relative number of flashes. SEE CHART.
4. The courtesy light switch off for 2 sec. Then it goes on again
for 5 sec. waiting for a transmission.
Key 1
+
5 sec.
Level 1: Light door
Level 2: Medium / light door
Level 3: Medium / heavy door
Level 4: Heavy door
Key 2
+
5 sec.
5. Transmit (within 5sec) with the ideal key according to the
CHART.
6. The courtesy light switch off for 2 sec and therefore it
visualizes the new level setted with the relative number of
flashes. SEE CHART.
TX KEY
FLASHING N° DESCRIPTION
Key 1
1
Key 2
2
Key 3
3
Key 4
4
To correct any one of the parameters, restart from point 1.
STEP BY STEP LOGIC
The step by step logic enables the following cycle operation:
OPEN - STOP - CLOSE - STOP - OPEN
AUTOMATIC LOGIC
The automatic logic enables the automatic closing after a
setted time.
FUNCTIONING
Start in opening
Start in closing
Start in pause
Photocell in opening
Photocell in closing
Photocell in pause
Current sensor in opening
Current sensor in closing
Stop in opening
Stop in closing
Safety rib in opening
Safety rib in closing
29
STEP BY STEP Logic
AUTOMATIC Logic
Pause time = 30 sec.
AUTOMATIC Logic
Pause time = 1,5 min.
AUTOMATIC Logic
Pause time = 3 min.
STEP BY STEP
AUTOMATIC
LOGIC
LOGIC
STOP
NOT PERCEIVED
STOP
REVERSE
-
CLOSE
NOT PERCEIVED NOT PERCEIVED
REVERSE
REVERSE
-
T.PAUSE RECHARGE
STOP
STOP
REVERSE
REVERSE
STOP
STOP
STOP
STOP
REVERSE 3 sec REVERSE 3 sec
REVERSE
REVERSE