When your house is unoccupied for longer than 3 days during the winter months always set
the humidistat down to 15% so that severe weather during you absence will not result in
condensation which might cause damage in your home.
BYPASS AIR ADJUSTMENT, SUMMER SHUTDOWN,
AND YEARLY MAINTENANCE
BYPASS AIR ADJUSTMENT
Sometimes there can be a static pressure differential that may cause an excess of air to flow
through the bypass tube, causing less airflow through the distant heat outlets in the house. It
may also blow water off the evaporator bad. In either case the air damper installed with the
bypass collar should by gradually closed until the condition is corrected. To close the damper
loosen the top screw and lift up on the damper and turn closed to the desired position. Damper
adjustment is another way of adjusting the amount of humidity being added to the house (the
less air bypassed the less humidity will be added.)
SUMMER SHUT DOWN
At the end of the heating season complete the following steps.
1. Turn the humidistat off.
2. Unplug the transformer.
3. Close off the water supply at the saddle valve.
4. Close the bypass damper.
67285036 Rev. B 11-14
YEARLY MAINTENANCE AND WINTER START UP
For detailed recommended maintenance schedule refer to the Maintenance and Trouble
Shooting Guide.
At the beginning of the heating season complete the following steps.
1. Inspect the water supply tube, water drainage tube, and Electrical wiring replace if required.
2. Plug in the transformer.
3. Turn on the water supply at the saddle valve and check for any leaks.
4. Open the bypass damper.
5. Test the operation of the humidifier and check for any leaks and complete any necessary repairs.