Technical Data - Samplex Power SMC-10 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10. technicAL DAtA

chARActeRiSAtion oF the oPeRAtinG PeRFoRMAnce
System voltage
own consumption
Dc inPUt SiDe
open circuit voltage solar module
(at minimum operating temperature)
Module current
Dc oUtPUt SiDe
load current
end of charge voltage
boost charge voltage
reconnection voltage (SoC / lVr)
Deep discharge protection (SoC / lVD)
oPeRAtinG conDitionS
Ambient temperature
FittinG AnD conStRUction
Terminal (stranded / solid wire)
Degree of protection
Dimensions
Weight
*1 SMC-10 is protected against reverse battery polarity together with polarity protected
loads. reverse battery polarity combined with short circuited or polarized load could
cause damages in load or regulator.
*2 The reverse-polarity protection of the solar module in a 24V system is only provided
up to an open-circuit module voltage of 36.
*3 lower value for nominal current, higher value for lowest current.
PRoPeRtieS
SMc-10
12V (24V)
< 4 mA
< 47V
10A
10A
13.9V (27.8V)
14.4V (28.8V)
50% 12.4V to 12.7V
(22.4V to 23.2V)
30% 11.2V to 11.6V
(22.4V to 23.2V)
-25°C to +50°C / -13°f
to +122°f
3.4 mm
/ 6 mm
2
AWG# 12 / 9
IP 32
145 x 100 x 24 mm /
5.71 x 3.94 x .94"
≈ 150 g / .33 lb.
SAMLEX AMERICA INC. | 7
-
2

Publicité

Chapitres

Table des Matières
loading

Produits Connexes pour Samplex Power SMC-10

Table des Matières