Installation - Samplex Power SMC-10 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Owner'S Manual |
The following protection functions are part of the basic function of the controller:
overcharge protection; Deep discharge protection; battery undervoltage protection;
Solar module reverse current protection.

4. inStALLAtion

4.1 Mounting location requirements
Do not mount the solar charge controller outdoors or in wet rooms. Do not subject
the solar charge controller to direct sunshine or other sources of heat. Protect the solar
charge controller from dirt and moisture.
Mount upright on the wall (concrete) on a non-flammable substrate. Maintain a
minimum clearance of 10 cm below and around the device to ensure unhindered air
circulation. Mount the solar charge controller as close as possible to the batteries (with a
safety clearance of at least 30 cm).
4.2 Fastening the solar charge controller
Mark the position of the solar charge controller fastening holes on the wall.
Drill 4 x 6 mm holes and insert dowels. fasten the solar charge controller to the wall
with the cable openings facing downwards, using 4 oval head screws M4 x 40 (DIN
7996).
4.3 connection
Use a wire size suited to the current rating of the charge controller, e.g. 6mm² for
10A for cable length of 10 m. An additional external 20A fuse (not provided) must be
connected to the battery connection cable, close to the battery pole. The external fuse
prevents cable short circuits.
Solar modules generate electricity under incident light. The full voltage is present, even
when the incident light levels are low. Protect the solar modules from incident light dur-
ing installation, e.g. cover them.
NeVer ToUCh NoN ISolATeD CAble eNDS. Use only insulated tools. ensure that all
loads to be connected are switched off. If necessary, remove the fuse.
Connections must always be made in the sequence described below:
1St Step: COnneCt the battery
-
Connect the battery connection cable with the cor-
rect polarity to the middle pair of terminals on the
solar charge controller (with the battery symbol).
-
If present, remove any external fuse. Connect bat-
tery connection cable A+ to the Positive pole of the
battery. Connect battery connection cable A– to the
Negative pole of the battery. Insert the external fuse
in the battery connection cable.
-
If the connection polarity is correct, the info leD
illuminates GreeN.