Emergency start

1. The device must be properly charged, with the four blue LEDs of the indicator
switched on.
2. Connect the red clamp to the positive terminal (+) of the battery, or to the remote
positive pole. Connect the black clamp to the negative pole (-) of the battery or to
the remote negative pole.
3. The connection must be realized with both sides of the clam firmly attached to the
metal. In case of sulphur deposits on the pole, these must be previously removed.
4. Turn the ignition key for a maximum of 3 seconds and then wait for a further 3
minutes before attempting to jump start again.
5. In case of particularly heavy starts, the integrated security system of the i-Starter
4.0 will shut off power supply after about 3 seconds.
6. When the engine is running, remove one clamp at a time, return the clamps to
their housing and recharge the starter as soon as possible.
Note: when the push button is pressed for over two seconds, the security function of
the device is inhibited for 30 seconds. Once the engine has been jump started, the
cables must be quickly disconnected from the battery in order not to overload it.
10
BLUE LED fixed:
Indicates correct
connection and Booster
charged. You can jump
start the engine.
BLUE LED flashing:
Indicates very low
battery. Press the push
button for two seconds
and then jump start the
engine.
BLUE LED flashing and
Beep, Beep
Beep, Beep
beeping:
Indicates reversed polarity.
Invert the connection
Beep, Beep
Beep, Beep
immediately.
BLUE LED: Switched off
and not beeping:
Indicates absent or
interrupted vehicle battery.
Press the push button for
two seconds and then jump
start the engine.