4.4. Manual operation

The flush-mounting motion detector has two modes. Besides the automatic or PIR mode (see section 4.3.), you
can also switch the lighting on and off manually.
Step
Action
1
Press the button on the top
of the sensor briefly (< 5 s):
2
Press this button again.
To block the shift to the manual mode, connect the voltage (the same phase as the power supply voltage) to the
external input terminal 1 (E1) of the actuator.
4.5. Staircase function
By briefly interrupting the voltage at the external input terminal 1 (E1) of the actuator via a push button (NO or
NC), the lighting is switched on for the duration of the preset switch-off delay if at that moment the daylight is
less intense than the preset lux value.

4.6. Parallel connection

In installations with several motion detectors that are connected in parallel, the lamps may not be illuminated
in the detection area of different motion detectors, because, for example, when the first sensor switches off the
lighting, the second sensor registers the lowering temperature and switches the lighting on again. The minimum
load required remains 40 W.

4.7. External push button

If you press the external push button, the lighting is switched on, just like when the sensor is activated. The
lighting is only switched on if the photo cell in the sensor registers that it is sufficiently dark in the room (the
daylight level falls below the preset lux value).
5. TROUBLESHOOTING
Problem
Cause
The flush-mounting motion
The reaction threshold is set to
detector does not switch on.
twilight in a brightly illuminated
room.
The lens is covered or dirty.
The electronic control gear or the
fuse is defective.
The wiring is faulty.
The lighting does not work.
The lamp is defective.
The flush-mounting motion
detector has been mounted at
the incorrect height.
The lighting remains illuminated.
The manual mode is activated.
You have switched on the lighting
using a switch.
There is constant movement in
the detection area.
The manual mode cannot be put
The manual mode is blocked.
into operation.
The manual mode is activated.
The lighting is constantly
The distance to the switched
switching on and off.
lamp is too small.
Automatic and unwanted
The flush-mounting motion
switching
detector switches on after
the mains voltage has been
interrupted.
Sunlight falls on the lens or in
the detection area.
Heat/cold penetrates through to
the detection area by way of an
8
open door or window.
EN
Result
- The lighting remains switched on for four hours.
- During this time, the red LED behind the sensor lens is also
illuminated.
- After four hours, the sensor resumes its normal operation
(automatic mode).
- The red LED switches off.
- The lighting is switched off.
- The sensor detects no movement for a period of ten seconds.
- After ten seconds, the sensor resumes its normal operation.
Action
Correctly set the light intensity
(lux value).
Uncover or clean the lens.
Replace the defective electronic
control gear or the defective
fuse.
Check the wiring.
Replace the lamp.
Respect the recommended
mounting height (0.8 – 1.2 m).
Deactivate the manual mode.
Switch off the lighting with the
switch.
- Remove the heat source from
the detection area.
- Set the switch-off delay to the
shortest possible time.
- Wait until the switch-off delay
elapses (max. 30 minutes).
- Cover the lens to check this
setting.
Deactivate the block (see section
4.4.).
Activate the automatic mode
and then the manual mode (see
section 4.4.).
Increase the distance to the
lamp.
The lighting is illuminated
for 90 seconds before the
interruption. After that, the device
is in automatic mode.
Set the lux value to twilight.
Close the door or window or
move the device.
nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu

6. TECHNICAL DATA

power supply voltage
mounting
connection terminals
ambient temperature during operation
ambient temperature during storage and transport
switch-off delay
light sensitivity
flush-mounting height
extra functionality
detection angle
detection range
8 m
7
6
5
4
3
2
1
0
1
2
3
4

7. WARNINGS REGARDING INSTALLATION

- The installation should be carried out by a registered installer and in compliance with the statutory
regulations.
- This manual should be presented to the user. It should be included in the electrical installation file, and it
should be passed on to any new owners. Additional copies are available on the Niko website or via the Niko
support service. The latest manual for this product is available on the Niko website at any time.
- During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this manual, which only states general regulations and should therefore be read within the scope of each
specific installation.
- the rules of proper workmanship.
8 m
This product complies with all of the relevant European guidelines and regulations. If applicable, you can find
the EC declaration of conformity regarding this product at www.niko.eu.
8. NIKO SUPPORT
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support
service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can
be found at www.niko.eu under the "Help and advice" section.

9. GUARANTEE PROVISIONS

- The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of
purchase of the product by the consumer. If there is no invoice, the date of production applies.
- The consumer is obliged to inform Niko in writing about the non-conformity, within two months after stating
the defect.
- In case of a non-conformity, the consumer only has the right to a product repair or replacement free of
charge, which shall be decided by Niko.
- Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or
careless use, incorrect operation, transformation of the product, maintenance that does not adhere to the
maintenance instructions or an external cause, such as damage due to moisture or overvoltage.
- The compulsory regulations of the national legislation concerning the sale of consumer goods and the
protection of the consumer in the countries where Niko sells, directly or via sister companies, subsidiaries,
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned
rules and regulations.
230 Vac, 50 Hz
flush-mounting box with flush-mounting depth of
min. 40 mm
6 (maximum capacity per connection terminal:
2 x 1.5 mm² or 1 x 2.5 mm²)
0 – 40°C
-25 – 70°C
10°
± 5 s – 30 min
± 2 – 1000 lux
0.8 – 1.2 m
staircase function
35°
horizontal: 180° – vertical: 60° (see illustrations
50°
below)
8 m (horizontal) (see illustrations below)
50°
5
6
7
8 m
7
6
5
4
3
2
1
0
1
2
3
4
5
6
PMXXX-7802XR14325