Regency Classic C34-NG10 Gaz Naturel Guide D'installation Et D'utilisation page 19

Autoportante poêle au gaz
Table des Matières

Publicité

Horizontal Venting with Two (2. 90
One 90
elbow = Two 45
o
o
Option
V
H + H1
A)
4' Min.
6' Max.
B)
5' Min.
7' Max.
C)
6' Min.
8' Max.
With these options, maximum total
pipe length is 30 feet with minimum
of 6 feet total vertical and maximum
8 feet total horizontal.
Please note minimum 1 foot be-
tween 90
elbows is required.
o
Lengths do not include elbow
indicated.
Vent restrictor position C (fully
open), refer to "Vent Restrictor
Position" section.
Vertical Venting with Two (2. 90
One 90
elbow = Two 45
elbows.
o
o
Option V
H
A)
1' Min.
4' Max. 2' Min.
B)
2' Min.
5' Max. 3' Min.
C)
3' Min.
6' Max. 4' Min.
D)
4' Min.
7' Max. 5' Min.
E)
5' Min.
8' Max. 6' Min.
Lengths do not include elbow indicated.
Vent restrictor position C (fully open), refer to "Vent Restrictor
Position" section
Elbows
o
elbows.
Elbows
o
V + V1
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
required.
elbows is
Regency C34-10 Poêle au Gaz à Évacuation Directe CLASSIC™
installation
|
19
|
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Classic c34-lp10 propane