Technical Data

Input
Nominal voltage U
:
N
Voltage range:
Nominal consumption:
Short-circuit protection:
Overvoltage protection:
Duty-cycle ON button:
Duty-cycle Reset button:
Safety function
Safety mat / safety edge (4)
max. permitted
safety edge contact resistance: 1000 Ω
switching current at short circuit: typ. 15 mA at U
Light curtains (8)
control current via S12, S22:
Min. voltage on terminals
S12, S22 when relay activated: DC 10 V
Output
Contacts
The NO contacts can be used for safe braking.
Delay t
v
ranges at /_ _0:
fixed at /_ _1:
Time setting in:
10% steps of
max. time range value
Repeat accuracy:
Thermal current I
:
th
Safety function
E-Stop (1) (6), Safety gate (2) (7),
Exclusive or contacts (5)
Start up at U
:
N
Release delay at U
and
N
disconnecting the supply:
Release delay at U
and
N
disconnecting S12,S22:
Simultaneity demand:
Two-hand control (3)
Start up at U
:
N
Release delay at U
and
N
disconnecting the supply:
Release delay at U
and
N
disconnecting S12,S22:
Simultaneity demand:
Safety mat (4)
Start up at U
:
N
Release delay at U
and
N
disconnecting the supply:
Release delay at U
and
N
disconnecting S12,S22:
Light curtains (8)
Start up at U
:
N
Release delay at U
and
N
disconnecting the supply:
Release delay at U
and
N
disconnecting S12,S22:
Simultaneity demand:
DC 24 V
0.8 ... 1.1 U
N
Typ. 3.2 W
Internal PTC
Internal VDR
0.1 s < t
< 3 s
EIN
> 3 s
N
typ. 8 mA at U
N
2 NO instantaneous contacts
2 NO delayed contacts
8 time ranges in one unit (seconds or
minutes) settable via rotational switch
0.1 ... 1
1.0 ... 10
0.2 ... 2
3.0 ... 30
0.3 ... 3
10 ... 100
0.5 ... 5
30 ... 300
other times on request
seconds or minutes
1, 2, 3, 5, 10, 30, 100, 300
other times on request
see formula
max. 8 A
(see quadratic total current limit curve)
< 65 ms
< 40 ms
< 60 ms
< 3 s
< 110 ms
< 40 ms
< 60 ms
< 0,5 s
< 85 ms
< 40 ms
< 60 ms
< 35 ms
< 40 ms
< 25 ms
< 1 s
Technical Data
Switching capacity
to AC 15:
to DC 13
Instantaneous contacts:
Delayed contact:
to DC 13
Instantaneous contacts:
Electrical life
at 5 A, AC 230 V cos j = 1:
Permissible operating frequency
instantaneous contact:
delayed contact:
Short circuit strength
max. fuse rating:
Mechanical life:
Semiconductor monitoring output
(not safety):
General Data
Nominal operating mode:
Temperature range
Operation:
Storage:
Altitude,
Clearance and creepage distance
rated impulse voltage /
pollution degree:
EMC
Interference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Climate resistance:
Terminal designation:
Wire fixing:
Mounting:
Weight:
Dimensions
Width x height x depth:
UG 6960 PS:
UG 6960 PC, PT:
21
3 A / AC 230 V
IEC/EN 60947-5-1
2 A / DC 24 V
IEC/EN 60947-5-1
3 A / DC 24 V
IEC/EN 60947-5-1
4 A / DC 24 V at 0.1 Hz
> 1.5 x 10
switching cycles
5
Max. 1800 switching cycles / h
Max. 360 switching cycles / h
6 A gG / gL
IEC/EN 60947-5-1
10 x 10
switching cycles
6
1 for instantaneous contact
1 for delayed contact
max. 50 mA DC 24 V, plus switching
(see quadratic total current limit curve)
Continuous operation
- 25 ... + 60 °C
(see quadratic total current limit curve)
At an altitude of > 2000 m the maximum
permissible temperature reduces by
0.5°C / 100 m
- 40 ... + 85 °C
IEC 60664-1
≤ 2000 m
> 2000 m up to ≤ 4000 m
4 kV / 2
2,5 kV / 2
IEC/EN 61326-3-1, IEC/EN 62061
Limit value class B
EN 55011
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
Thermoplastic with VO behaviour
according to UL subj. 94
Amplitude 0,35 mm
Frequency 10 ... 55 Hz, IEC/EN 60068-2-6
25 / 060 / 04
IEC/EN 60068-1
EN 50 005
Captive slotted screw
or cage clamp terminals
DIN rail
IEC/EN 60715
Approx. 250 g
22.5 x 110 x 120.3 mm