4008 RV REVOLUTION™ BY-PASS PUMP
®
INSTALLATION & OPERATION MANUAL
16 AWG [1.28mm] or heavier wire
Connector
Switch
Ground
Surface Solide
Black
Flexible Braided
High Flow Hose
INSTALLATION PREPARATION
The goal of installation is to provide a
quiet, easy-to-maintain installation with
good flow and low backpressure. This
can be accomplished with the following
guidelines:
❚ Mount on a solid surface in an
accessible location for strainer cleaning
and pump maintenance.
❚ 1/2" Male threaded models are intended
to be used with SHURFLO swivel barb
fittings which seal with an internal taper
when hand tightened. CAUTION: Sealers
and Teflon tape may act as lubricant
causing cracked housings or stripped
threads due to over-tightening. Sealer
may enter the pump inhibiting valve
action, causing no prime or no shut-off. A
failure due to foreign debris is not covered
under warranty.
❚ Use flexible high-pressure hose on the
pump inlet and outlet [such as SHURFLO
Kit 94-591-01]. The pumps ports and
strainer should not be connected to
plastic or rigid pipe, or the pump's
normal motion will transmit through rigid
plumbing causing noise, and possibly
loosening or cracking components.
FLOW MANAGEMENT SOLUTIONS
Fuse
Red lead (+)
Typical Pump Installation
❚ Pump must use an adequate 50-mesh
strainer [such as SHURFLO 255 series
strainers].
❚ Use a minimum of 1/2" [13mm]
Inner Diameter plumbing. Smaller ID
plumbing will cause cavitation, high
back pressure, low flow and noise.
❚ No need for an accumulator with by-
pass pumps.
❚ Pump is designed for intermittent
duty only: Do not use these pumps
for running a Reverse-Osmosis [RO]
Filtration System. High pressure-
continuous duty usage will shorten
the life of the pump and is not covered
under warranty.
❚ Wire Size is 16 GA MINIMUM, 12GA
is recommended —See Wire Chart in
Electrical Section for minimum sizing.
❚ Minimum power requirement is a 10
Amp circuit.
❚ Reduce restrictions on inlet and
outlet. This includes small inner
diameter shut-off valves, winterizing
valves and elbows.
911-1008 REV. K
Strainer
INSTALLATION GUIDELINES
❚ Solid Surface within 6' of tank.
❚ Minimize flow restrictions in the
system.
❚ No Accumulator needed.
❚ Flexible hose on inlet and outlet.
❚ Minimize plumbing elbows and valves.
❚ Accessible location.
❚ Strainer on pump inlet.
❚ Properly Sized wiring.
❚ Properly electrical protection.
❚ Properly sized plumbing.
❚ If the RV has an Intellitec Pump
Controller, it must be rated at 10 or 15
amps; If the controller is rated at 7.5
Amps, a new controller or a high-amp
relay must be used.
MOUNTING
❚ Mount the pump within 6 feet of the
tank for best performance and pump
life. The pump will pull farther, but the
farther it pulls the more work it does,
increasing vibration and noise, and
reducing the output and pump life.
❚ Mount pump in a space of at least 1
cubic foot for adequate ventilation to
prevent overheating.
❚ Pump may be mounted in any position.
❚ Mount pump for easy access for
cleaning strainer, maintenance and
service.
❚ Mount pump on a solid surface to
prevent vibration and noise.
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Pentair SHURFLO 4008 RV REVOLUTION

  • Page 1 SHURFLO 4008 RV REVOLUTION™ BY-PASS PUMP ® INSTALLATION & OPERATION MANUAL 16 AWG [1.28mm] or heavier wire Connector INSTALLATION GUIDELINES Fuse Switch Red lead (+) ❚ Solid Surface within 6' of tank. ❚ Minimize flow restrictions in the system. Ground Surface Solide ❚...
  • Page 2 ELECTRICAL ABOUT THE BY-PASS NOTE: By-pass adjustment should only ❚ The pump works best on an individual ing the switch screw in clockwise will be performed by a professional techni- filtered circuit, protected by the recom- raise the shut-off pressure. Unscrew- cian with proper gauges and equipment.
  • Page 3: Repair Kits

    TROUBLESHOOTING Vibration induced by driving can loosen RAPID CYCLING LEAKS FROM PUMP HEAD OR SWITCH plumbing, strainers and pump hard- √ For restrictive plumbing and flow √ For loose screws at switch or pump ware. Check for system components restrictions in faucets/shower head.
  • Page 5: Montage

    SHURFLO DÉRIVATION 4008 POUR VÉHICULES DE LOISIRS ® MANUEL D’INSTALLATION ET DE MAINTENANCE 16 AWG [1.28mm] Connector INSTRUCTIONS D’INSTALLATION Fusible Interrupteur Fil rouge (+) ❚ Surface solide à 2 m (6 ft) du réservoir. ❚ Minimiser les restrictions de débit dans le circuit.
  • Page 6: Électricité

    ÉLECTRICITÉ AU SUJET DE LA DÉRIVATION ❚ La pompe fonctionne le mieux sur un cir- REMARQUE : le réglage de la dérivation ne vis du manocontact dans le sens contraire cuit filtré individuel, protégé par l'utilisation doit être effectué que par des techniciens des aiguilles d'une montre pour diminuer la professionnels utilisant des manocontacts et d'un fusible ou d'un court-circuit spécifié...
  • Page 7: Dépannage

    DÉPANNAGE Les vibrations provoquées par CYCLE RAPIDE √ Pour la présence d’air dans le circuit. l'entraînement peuvent desserrer la tuy- √ Pour une plomberie restrictive et des Vérifiez l’absence d’air dans tous les auterie, les filtres et la visserie de la pompe. restrictions de débit dans l es robinets/ dispositifs et purgez le circuit.
  • Page 8 3545 HARBOR GATEWAY SOUTH, SUITE 103, COSTA MESA, CA 92626, (800) 854-3218 WWW.SHURFLO.COM All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.