Troubleshooting; Poor Water Pickup; Technical Specifi Cations - U.S. Products AGITATOR 16 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING

If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your U.S. Products Service
Center immediately for service.
TRIPPING THE CIRCUIT BREAKER
The Circuit Breaker (17) is located on the Operator's Handle; it protects the electrical circuit and brush motor from damage due to overload
conditions. If the circuit breaker is tripped try to determine the cause.
Brush Circuit Breaker (5 Amp) Possible cause may be:
1
Debris wrapped around the brush drive (remove debris)
2
Brush setting too low (adjust to proper brush setting)
3
Electrical short circuit (have your U.S. Products Service Center or qualifi ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. If
the circuit breaker trips repeatedly, call your U.S. Products Service Center for service.

POOR WATER PICKUP

Possible causes may be:
1
Recovery Tank Full (empty recovery tank)
2
Open recovery tank drain hose (secure drain hose cap or replace)
3
Recovery hose not connected at vacuum shoe (connect hose to vacuum shoe)
4
Recovery hose is kinked or damaged (replace the hose)
5
Recovery tank cover gasket leak (replace gasket)
6
Debris caught in vacuum shoe or recovery hose (clean vacuum shoe and recovery hose)
INADEQUATE OR NO SOLUTION FLOW
Possible causes may be:
1
Solution tank empty (fi ll solution tank)
2
Solution lines or screen clogged (fl ush lines and screen)
3
Spray Nozzles Clogged (clean nozzles)
4
Faulty Pump (contact an authorized service person)
5
Variable Flow Control Knob incorrectly set on Clean & Restore model (adjust knob)
INADEQUATE OR NO CHEMICAL INJECTION
Possible causes may be:
1
Chemical tank empty (fi ll chemical tank)
2
Chemical tank feed hose restricted or damaged (clean tank & remove hose restriction)
3
Injector check valve clogged (disassemble and clean)
4
Clogged or incorrect injector meter nozzle (clean & check chemical ratio / install correct nozzle)
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Model No.
Voltage/frequency
Rated Current
Sound Pressure Level (ISO 11201)
Total Weight
Dry Weight
Vibrations at the Hand Controls (ISO 5349-1)
Solution Tank Capacity
L x W x H
Agitator
16
56266115
V/Hz
120 / 50-60
Amp
12.5
dB (A)/20μPa
68
lbs/kg
170 / 77
lbs/kg
116 / 52
m/s
0.72m/s
2
2
8 gal (30.3l)
inches
44.5 x 19.5 x 37
FORM NO. 56041707 - Agitator
EN
Agitator
18 Clean & Restore
56266116
120 / 50-60
12.5
68
217 / 98
121 / 55
0.72m/s
2
13 gal (49.2l)
44.5 x 19.5 x 37
16 / 18 Clean & Restore - A-19
ENGLISH / A-19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Agitator 185626611556266116

Table des Matières