Connection With The Mains; Adjusting The Angle Of Inclination; Operation; Cleaning And Maintenance - EuroLite SKY BEAM Mode D'emploi

Spot extérieur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power-plug.
The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

Adjusting the angle of inclination

You can adjust the angle of inclination by loosening the fixation screws on the suspension of the projector-
head.
Adjust the desired angle of inclination and tighten the fixation screws.

OPERATION

After you connected the effect to the mains, the SKY BEAM starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
DANGER TO LIFE!
DANGER TO LIFE!
International
L
N
21/43
00026549.DOC, Version 1.4

Publicité

Table des Matières
loading

Table des Matières