6. Electrical work
6.3.3 How to set the fixed up/down air direction
(Only for wired remote controller and PUHZ, PU(H) application)
• Only the particular outlet can be fixed to certain direction with the
procedures below. Once fixed, only the set outlet is fixed every time air
conditioner is turned on. (Other outlets follow UP/DOWN air direction
setting of the remote controller.)
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
• "Up/Down air direction" is the direction (angle) to fix.
Reset
1
2
horizontal
Manual vane angle
MITSUBISHI
ELECTRIC LABEL
Select:
Outlet
F1
Manual vane angle
If all outlets are selected,
next time the unit goes into operation.
Navigating through the screens
• To go back to the Main menu ..........[MENU] button
• To return to the previous screen .....[RETURN] button
1
3
4
5
Angle
F2
F3
F4
Setting
will be displayed the
Horizontal airflow
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
Outlet No.3
Outlet No.2
Note: "0" indicates all outlets.
The current vane setting will appear.
Select the desired outlets from 1 through 4 with the [F1] or [F2] button.
• Outlet: "1", "2", "3", "4", and "1, 2, 3, 4, (all outlets)"
Press the [F3] or [F4] button to go through the option in the order of "No setting (re-
set)", "Step 1", "Step 2", "Step 3", "Step 4", and "Step 5".
Select the desired setting.
■ Vane setting
No setting
Step 1
Step 3
Step 4
All outlets
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 4) when the
transmission is completed.
Make the settings for other outlets, following the same procedures.
Downward
Fixed setting
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be fixed
horizontally to avoid direct airflow.
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
Step 2
Step 5