Automatic Deactivation - Toyotomi Kero-Sun LC-3000 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
H
tHe infORMatiOn DisPlay
The information display K not only serves as an indicator of the (set) time and temperature (Sections C,
E, and F), it also indicates any malfunctioning of the heater. The code on the information display tells you
what is the matter:
cODe
infORMatiOn
e - 0
Temperature within the heater too high.
f - 0
Power interrupted.
e - 1
Faulty thermostat.
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
Re-ignite the heater immediately after
e - 23
extinguishing.
e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 32°C.
e - 8
Defective booster.
e - 8 1
Abnormal frequency.
e - 9
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 65 hours
and has turned itself off automatically.
Out of fuel.
-- : --
+
Too little ventilation.
-- : --
+
Always contact your dealer for any malfunctioning not listed above and/or when
the error keeps occuring after taking the corrective measure as described above.

autOMatic DeactivatiOn

This heater is fitted with a safety system that ensures that it switches off
automatically after 65 hours continuous operation. The following will then appear
in the display:
. If desired, you can switch the heater on again by pressing
the
button L (see Section D).
autOMatic cleaninG MODe
When the heater has been burning continuously for two hours at its highest
setting, the burner will automatically start an autoclean procedure. The display
will show the autocleaningcode cl:05 running back to cl:01. The procedure takes 5
minutes, during which the heater will burn at its lowest setting, while the burner
autocleans. When the burner is clean again, the heater will automatically switch
back to the highest setting again.
i
cHilDPROOf lOcK / PaRental cOntROl
The childproof lock can be used to prevent children accidentally changing the
heater settings. When the heater is burning and the childproof lock is on, the
heater can only be switched off. Other functions are blocked then. If the heater
has already been switched off, the childproof lock also prevents accidental ignition
of the heater. Activate the childproof lock by pressing the appropriate key M and
holding it down for more than 3 seconds. The KEY-LOCK indicator
the information display (Fig. I), indicating that the childproof lock has been activated.
Switch off the childproof lock by pressing the key M and holding it down for more
than 3 seconds once again.
4
8
WHat tO DO
Cool-down and re-ignite.
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Wait for approx. 30 sec.
and re-ignite after inserting
the plug again.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Insert the plug into the wall-socket again.
Contact your dealer.
Clean filter.
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Ventilate better.
will appear on
In case of any
malfunctioning the
information display will
tell you what is the
matter.
I: When the
mark
appears, the childproof
lock has been activated.

Publicité

Table des Matières
loading

Table des Matières