DIAGRAM 3a - ELECTRICAL SUPPLY CONNECTIONS
BLK
BLK
BLK
BLK
FUSE
FUSE
120V
120V
SUPPLY
SUPPLY
BLK
BLK
REQUIRED
REQUIRED
OUTLET
OUTLET
GRN
GRN
WHT
WHT
WHT
WHT
WHT
WHT
(COMPONENT POSITIONS ARE NOT EXACTLY AS SHOWN IN DIAGRAM)
Adjusting the Water Temperature:
The ideal drinking water temperature is between 3 deg.C. (37 F.) and 5 deg.C.
(41F.). The thermostat is factory set to medium which is suitable for many
climates and can be adjusted to suit conditions by removing the wiring box
cover. Turn the control higher or lower as required (see Diagrams 3a & 3b).
The pilot light (not available on LW50) comes on whenever the thermostat is
activated, which aids in selecting the temperature setting. The heating element
can only be tested for working condition by sensing warmth coming from it.
If the water is too cold then turn the control higher until the pilot light comes
on. This sets the low temperature setting. It is better to adjust one increment
at a time and let the control react over time to the change to prevent
overshooting the desired low temperature.
Maintaining the Waterer:
The CANARM waterer is designed for easy cleaning and is virtually
maintenance free. To clean the bowl, remove the pin holding the bowl down,
clear the catch with the latch and swing the bowl up and over to empty the
dirty water.
The low maintenance valve/float assembly (Diagram 4) should be checked
and cleaned based on quality of water supply. Simply pull pin to remove piston
assembly from valve housing. Inspect and clean orifice in housing. Remove
any rust and mineral build up. Careful not to damage the smooth continuous
orifice ridge that the seal comes in contact with. Inspect rubberized seal and
O-ring for dirt or damage, and replace if necessary.
Valve & Float Kit Assembly Diagram (DIAGRAM 5):
Step 1: Slide threaded portion of P4875 Brass fitting up through
bowl deck along with G4957 Hose Bracket (see diagram) and
fasten from below using P4877 Brass Nut supplied in kit.
Step 2: Screw on P4876 Brass elbow onto P4875 Brass fitting
oriented towards, or into Bowl. (Ensure Teflon tape is applied to
threads)
Step 3: Screw on the P4300 Plastic Valve to the end of the
P4876 Brass elbow oriented water supply orifice facing down into
bowl. (Ensure Teflon tape is applied to threads)
Step 4: Mount the P6985-1620Q long Set Screw to the end of the P4836
Plastic Ball Float using an Allen wrench. Fully thread these to the P4300 Plastic Valve.
Step 5: Adjust the P4300 Plastic Valve according to desired water height. (Gently lift P4836 Plastic Ball Float up until Valve stops, and closes.
This is your set point)
Step 6: Mount G4924 Cover and secure with the four supplied P6373-1620 nylon lock nuts.
M0003 - 10/21/15
MARRETT/WIRE-NUT
MARRETT/WIRE-NUT
Knockout
Knockout
(for power
(for power
supply wires)
supply wires)
BLU
BLU
BLU
BLU
GRD.
GRD.
LUG
LUG
Not used on
Not used on
LW50 model.
LW50 model.
DIAGRAM 3b - ELECTRICAL SUPPLY CONNECTIONS
MODEL H200
HEATING
HEATING
ELEMENT
ELEMENT
120V
120V
SUPPLY
SUPPLY
REQUIRED
REQUIRED
PILOT
PILOT
LIGHT
LIGHT
(COMPONENT POSITIONS ARE NOT EXACTLY AS SHOWN IN DIAGRAM)
4" Plastic Ball Float (Kit: H0-P4836)
DIAGRAM 4 -
VALVE AND FLOAT ASSEMBLY
SEE NOTES FOR MAINTENANCE
SEE NOTES FOR MAINTENANCE
DIAGRAM 5 - ASSEMBLY DIAGRAM
P4876
BRASS ELBOW
P4877
BRASS NUT
P4875
BRASS FITTING
P4822
HOSE CLAMP
G4958 - FLEXIBLE HOSE
G4958-H200 (FOR H200)
MARRETT/WIRE-NUT
MARRETT/WIRE-NUT
Knockout
Knockout
BLK
BLK
(for power supply wires)
(for power supply wires)
BLK
BLK
BLU
BLU
FUSE
FUSE
BLU
BLU
GRD.
GRD.
BLK
BLK
LUG
LUG
OUTLET
OUTLET
GRN
GRN
WHT
WHT
WHT
WHT
WHT
WHT
Valve Main Assembly
(Kit: H0-P4300)
(H200 - HO-P4305HF)
1.5" 1/4-20 S.S. Link Arm (Kit: H0-P4300)
P4300 - PLASTIC VALVE
P4305-HF (FOR H200)
G4957
HOSE BRACKET
HEATING
HEATING
ELEMENT
ELEMENT
PILOT
PILOT
LIGHT
LIGHT
Not used on LW50
Not used on LW50
model.
model.
P6985-1620Q
1 1/2" SET SCREW
P4836
4" PLASTIC BALL FLOAT