electrical information
EN

9.1.1 wiring diagram

Control Board
9.2
wiring to wall switch & remote control (in series)
1. Determine the location for the wall switch. Install an electrical box (not supplied) at the location.
2. Ensure the hot and neutral wires from the Proflame 2 are properly connected to the wall switch box.
3. Connect the hot wire from the on/off switch to the wall switch.
4. Connect the neutral wires to each other from the blower to the power source neutral (N).
5. Connect the all ground from the SIT Proflame 2 control board to the blower.
note:
Check the blower specifications (see "blower specifications" section) before choosing a suitable wire size.
9.2.1 wiring diagram
Control Board
28
W415-1789 / C / 01.29.19
SIT
Proflame 2
14/2 power source
(not supplied)
L
N
Legend:
Ground Connection =
Field Connection =
Neutral =
L1 (120VAC) =
Ground Wire =
SIT
Proflame 2
G
L
N
Legend:
Ground Connection =
Field Connection =
On/Off Switch
in Blower
Housing
On/Off
Switch
(supplied)
(factory installed)
On/Off Switch
in Blower
Housing
Wall
On/Off
Switch
Switch
Blower
Blower