INSTALLATION
The smoke detector is to be mounted on the ceiling or on the wall, if necessary. Since
the smoke detector is a single-station type, it cannot be linked to other detectors.
WARNING:
Do not connect the smoke detectors to any other alarm or auxiliary device.
Connecting anything else to this detector will prevent it from working properly.
Read the "Where To Install Your Smoke Detector" and "Where Not To Install Your
Smoke Detectors" sections in this Manual before installing. To install the detector,
perform the following steps (see Figure 7).
Select the installation location.
Remove locking pin securing the
mounting bracket to the unit (see
Figure 7).
Remove the mounting bracket
from the unit by rotating it
counterclockwise.
Use the bracket as a template for
marking the mounting holes
Using an appropriate drill, drill two
holes at the marks and insert
anchors.
Using screws (supplied) attach the
bracket to the wall as in Figure 7.
Open the batteries compartment
cover (see Figure 8).
Observing proper polarity, insert a
2xCR123 3V Lithium batteries
(supplied) into the batteries
compartment and close the
compartment cover.
Write message is sent
automatically, 10 seconds after
placing the batteries, or by
pressing the detector's tamper for
a period of 3 seconds.
Line up the side slot of the bracket
and the detector. Push the
detector onto the mounting
bracket and turn it clockwise to fix
it into place.
Insert the locking pin in order to
secure the mounting bracket to
the detector (see figure 7).
Pull the detector outward to make
sure it is securely attached to the
mounting bracket.
Wireless Supervisor Photoelectric Smoke Detector
Locking Pin
Bracket
Figure 7: Smoke Detector Installation
Battery Compartment
Tamper
Figure 8: Batteries Compartment/Tamper
WARNING:
This detector is not suitable for installation in a
hazardous location, as defined in the national
electrical code. Do not use detector in an outlet
controlled by a wall switch.
Detector
Screws
EN
9