Pre-installation
Upon delivery the Solar Charger Unit is installed as follows:
-
Gas control active (see functions)
The above functions can be turned off at any time.
Gas control de-activate
1.
Unscrew the 4 screws (see diagram) on the Solar Charger Unit and carefully remove the sassing/lid.
2.
Disconnect the jumper J6. The gas control is now de-activated.
Installation – Warning: Take care that the Terminals/Poles correspond!!!
The Solar Charger Unit should be placed in close proximity to the battery and be sufficiently protected against the weather. Take care to place
the battery in a well ventilated place. To enable the unit to function properly, the electrical connections should face downwards. To guarantee
that the unit functions properly it must be connected to the solar generator, the lead-battery and the load.
Each part of the system-solar generator, lead battery, load and Solar Charger Unit should have the corresponding power supply. Please check
each component before installation, when in doubt contact a specialist! Take careful attention on the following installation instructions:
1.
Connect the battery to the corresponding terminals on the Solar Charger Unit. To prevent the wiring from overheating and power supply
reduction the use of cable/wire 2.5 mm² flexible is recommended. Use always fuse to connect to the battery +terminal/pole. Both
components must be installed close together in the same room.
2.
Connect the solar panel to the corresponding terminals on the Solar Charger Unit.
3.
Connect the load to the Solar Charger Unit. The connection-terminals pictured on the Solar Charger Unit or see diagram.
Temperature sensor
Battery – complete loading The LEDs indicate the level of recharging. The present charging level of the solar panel and possible
Protection against over discharge (LED red)
By over discharge the load is automatically switched off and the LED is red. When the rechargeable battery is recharged, the LED does not
illuminate. The rechargeable battery is ready to be used.
The Solar System fails to Function – possible reasons
Battery terminals/poles are wrongly connected: Avoid at all costs!!!
Load terminal/poles are wrongly connected: The apparatus can be seriously damaged before the fuse blows. Batteries contain considerable
amounts of electrical energy. A short-circuit can result in a large build-up of heat leading to FIRE!!
Two LEDs indicate the operating conditions under different circumstances and possible mal-functions in the Solar Charger Unit.
LED
LED red
During the day
green
1 OFF
OFF
No flow of charging current
Check flat fuse
2 ON
OFF
Flow of charge current
Battery is charging
3 OFF
ON
No flow of charging current
4 ON
ON
Battery empty
Flow of charge current
Specifications
Nominal voltage:
Charging current (solar cells):
max. Load:
max. Power use:
Final charging voltage:
-
normal:
-
gassing deactivated:
-
temp. compensation:
Over discharge disconnection:
-
constant:
-
reset voltage:
Gas regulation:
-
gassing activation voltage:
-
final gassing voltage:
-
temp. compensation:
Fuse:
Temperature range:
Measurements (L x W x H):
Weight:
Subject to technical alternation. No responsibility will be taken for printing mistakes. V3_10/2020
Phone: (49) 9622 – 719910, Fax: (49) 9622 – 7199120 info@ivt-hirschau.de www.ivt-hirschau.de
Should be attached closed to the battery.
disturbances.
12/24 V
20 A
20 A
4 mA
13.7 V/27.4 V
14.1 V/28.2 V
-4 mV/K/cell
11.1 V/22.2 V
12.6 V/25.2 V
12.4 V/24.8 V
14.5 V/29 V
-3 mV/K/cell
20 A
-25 °C - +50 °C
175 x 100 x 45 mm
350 g
IVT Innovative Versorgungstechnik GmbH, Dienhof 14, D-92242 Hirschau
At night
No flow of charging current
Check flat fuse
Load does not work although fuse
o.k.
Strong light of green LED
Battery empty
Additional note
Deep discharge not active
Module poled; Consumer short-circuit
Remove cause of defect
Charge control defect.
The green LED reduces luminous intensity
when reaching the charging limit
Charge control defect
Load disconnection active
Consumer switched off
Check poles, interruption
Load is automatically switched on after
reaching the minimum charge