1 - TECHNICAL SPECIFICATIONS

Supply voltage:
Working:
Time remaining from when "Battery Low" symbol:
Type of action, disconnect and device:
Type of output:
Software:
Wire section to relay terminals:
Input (telephone programmer):
Wire section to telephone programmer input terminals:
Insulation:
Protection degree:
Pollution:
Ambient temperature indicator resolution:
Ambient temperature display range:
Frost protection temperature:
Differential operation:
Thermal gradient:
Operating temperature limits:
Storing temperature limits:
Reference standard for CE mark:
Note:
when room temperature flashes, display scale (-5°C or 39°C) has been exceeded.
Err
indica
tes that heat control activity has been suspended due to probe error.
N° 2 alkaline 1,5 V type AA (LR6)
2 years
1 month approx.
1/ B /U / Electronic
Relay with single-pole changeover contact,
voltage free, NO / COM / NC - max 8(2)A/250 V ac
Class A
2
2
0,75 mm ÷ 2,5 mm
for NO contact, zero potential
2
2
0,5 mm ÷ 1,5 mm
Class II
IP 30
Normal
0,1 °C
- 5 °C ÷ 39 °C
5 °C
Settable from 0,2 °C to 2 °C (default 0,3 °C)
max 1°K / 15 min
- 5 °C ÷ +50 °C
-10 °C ÷+ 65 °C
LVD
EN60730-2-7 EN60730-2-9
EMC
EN60730-2-7 EN60730-2-9
G
B
25