sigfox TEMP- Guide utilisateur / User guide version V2.0.0
3.4.2 Network registers
The list of registers below allows you to change the behaviour of the product application. This list is accessible in Provider mode following
execution of the ATT63 Provider command.
These registers must be handled with caution because they could cause problems of communication or of non-compliance with the legislation in
force.
Register
202
Number of repetitions in the case of a uplink
frame associated with a downlink frame
317
Enabling the respect of the Duty Cycle
Description
Coding
Decimal
Default: 2
Min/max: 0 to 2
Unit: none
IMPORTANT:
This number of repetitions only concerns the uplink
frames after which the product will open a listening
window for a downlink frame.
Decimal
Default : 1 (enabled)
Min/max : 0 (disabled) à 1 (enabled)
Unit: none
WARNING :
Deactivation of the Duty Cycle may result in a viola-
tion of the conditions of use of the frequency band,
depending on the use of the product, thus violating the
regulations in force.
In the case of disabling the Duty Cycle, the responsibi-
lity is transferred to the user.
Details
Page
61
of 79
FR
EN