sigfox TEMP- Guide utilisateur / User guide version V2.0.0
1.4. Technical Specifications
1.4.1 General characteristics
Parameters
Supply voltage
Maximum current
FR
Power supply:
Working temperature
Dimensions:
Weight
Casing
EN
Radio standards
1.4.2 Autonomy
Operating conditions:
Product shelf life before use: Maximum 1 year.
Calculations performed at a temperature of 20°C
Without super-sampling factor in the period
The above values are estimations based on certain conditions of use and environment. They do not represent a commitment on the part of
adeunis®.
1.4.3 Sensor characteristics
Caracteristics
Internal sensor - temperature range
Internal sensor - Inertia by 10°C steps
External sensor - temperature range
External sensor - Inertia by 10°C steps
External sensor - Cable length
Resolution
Precision
Value
Nominal 3.6V
90mA
Removable battery version: SAFT LS14500
-25°C / +70°C
105 x 50 x 27mm
130g
IP 67
EN 300-220, EN 301-489, EN 60950
Sending periodicity
Autonomy SF7
140 frames/day
4 month
100 frames/day
6 month
50 frames/day
11 month
20 frames/day
2.2 years
10 frames/day
4.2 years
2 frames/day
13.6 years
-30°C .. +70°C
90 minutes
-55°C..+155°C
15 minutes
2 meters
0,1°C
+/- 0,1°C
Page
48
of 79