Installing The Outdoor Vents; Recommended Installation; Installing The Vents - Fantech HERO Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLING THE OUTDOOR VENTS

RECOMMENDED INSTALLATION

36"
36"
(1 m)
(1 m)
18"
18"
(460 mm)
(460 mm)

INSTALLING THE VENTS

A well designed and installed ducting system will
allow the HRV to operate at its maximum
efficiency.
• The inner liner of the flexible insulated duct
must be secured to the sleeve of the hood
(as close to the outside as possible) and to
the appropriate duct connection on the HRV.
• The insulation should remain full and not
crushed.
1. Cut hole between wall studs
4. Seal using outdoor rated caulking
3'
3'
(900 mm)
(900 mm)
min.
min.
• The outer liner, which acts as a vapor
barrier, must be completely sealed to the
outer wall and the HRV using tape and/or
caulking.
• A good bead of high quality caulking
(preferably acoustical sealant) will seal the
inner flexible duct to both the HRV duct
connection and the hood prior to securing
them.
2. Insert vent
5. Attach insulated duct from inside and tape
Intake
• Should be located upstream of prevailing
winds from exhaust
• At a minimum of 900 mm (3') away from
dryer vents and furnace exhaust (medium
or high efficiency furnaces), driveways, oil
36"
36"
fill pipes, gas meters, or garbage
(1 m)
(1 m)
containers.
• Do not locate in the garage, attic, crawl
space, or underneath deck.
Locating the Exhaust Weatherhood
• Not near a gas meter, electric meter or a
walkway where fog or ice could create a
hazard
• Do not locate in a garage, workshop or
other unheated space
• To minimize airflow restriction, the flexible
insulated duct that connects the two
outside weatherhoods to the HRV should
be stretched tightly and be as short as
possible.
• Twisting or folding the duct will severely
restrict airflow.
3. Secure vent with proper screws
5

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

428486Hero 120hHero 150hHero 200hHero 150h-ecHero 250h-ec

Table des Matières