Bf 4; Bf4 Disassembly - Nilfisk Hybrid Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. BF 4

5.1. BF4 Disassembly

In this section, all components that need to be exchanged to use the new inverter are removed.
Do not forget to keep the display box and pressure sensor to be used in the installation section.
1. Switch off the electricity supply.
-
Turn off the main switch.
-
Turn off the inverter.
-
Remove the power cable from the main switch.
2. Turn off the water supply.
3. Open an outlet to depressurize the system.
Danger:
A dangerous situation.
Possible consequences: Death or severe injury prevention.
Danger:
Risc of electric shock!
Possible consequences: Death or severe injury prevention.
Hot Surfaces
Risc of burns!
Possible consequences: Severe injuries prevention.
Wait 180 seconds from turning off the inverter before continuing.
4. Remove the motor cable and motor temperature cable.
5. Remove 3x sensor cables from the pump top, flow switch and pump outlet.
6. Remove the inverter cap.
7.
Remove the display plug from the inverter.
8. Remove the display box.
-
Remove the old display from the display box.
-
Keep the display box for later installation.
9. Remove the inverter and inverter fitting.
10. Remove the plug from the outlet pipe.
11. Remove the pressure sensor from the pump top - keep the pressure sensor for later installation.