Transmitter installation inside the wire system

1)
Choose the position of the Transmitter, fix it at the wanted height and adjusted as precisely
as possible in the direction where the Receiver will be mounted.
2)
Position the 4 dip-switches depending on the chosen work frequency.
3)
Connect the power supply (from 11.5V
Transmitter, by switching on the red LED; by removing the bridge S1 (Led Off), the LED can
be disabled to decrease absorption.
4)
Connect the TT clamps of the electronic board tamper to the tamper proof line of the control
unit.

Receiver installation inside the wire system - UNIVERSAL

1)
Install the Receiver in the envisioned support point, at the same height as the Transmitter.
2)
Position the 4 dip-switches depending on the chosen work frequency.
3)
Connect the power supply (from 11.5V
4)
Upon commissioning, the LED and buzzer, if enabled, will flash for a stabilising time
5)
Connect the C and N.C. alarm outputs and the "FF" disqualification signal output to the
detection line of the control unit and the electronic board tamper TT clamps to the tamper
proof line of the control unit.
E

Receiver installation inside the wire system - SERIAL

N
1)
Install the Receiver in the envisioned support point, at the same height as the Transmitter.
G
2)
Position the 4 dip-switches depending on the chosen work frequency.
3)
Connect the power supply (from 11.5V
4)
Upon commissioning, the LED and buzzer, if enabled, will flash for a stabilising time
5)
Connect the DA and DB serial communication clamps on the barrier, to the respective on
the satellite. The alarm signals, tampering, fault and all technical signals will be reported
using this connection.
SO
DA
DB
USB
Should installation envision more points, the installed barriers must be addressed using
the dip-switch, on the electronic board of the same barriers.
The numbering of the barriers must be progressive and there cannot be more peripherals
with the same serial address.
Main warning for the wiring system
We recommend reaching the two units by means of flexible and water proof plastic
piping and carry out connections using shielded conductors.
The choice of section of the conductors to use for the connections must be carried out
depending on the distance from the power supply source, to guarantee a continuous
minimum voltage of 12 Vol, on both units. Malfunctioning may occur should the power
supply voltage drop below such value.
SS
Towards the
SI
other barriers
to 15V
) and check the functioning of the
to 15V
) to the positive + and negative - clamps.
to 15V
) to the positive + and negative - clamps.
• It is possible to connect on the same serial
port RS485, up to 32 barriers.
• We recommend shielded cables with four
wires of 0.5 mm each.
• The total length of the connection cable can
be 600 meters and must be subdivided for
all connected electronic boards.