Technical Data

Mechanical Data
Mechanical principle:
Enclosure:
Internal parts:
Locking force:
Degree of protection:
Locking module principle:
Magnetic principle:
Operating speed
min. / max.:
Input
Nominal voltage U
N
(Measured nominal voltage): AC/DC 24 V
Nominal voltage range:
Power consumption:
Output
Contacts
Door position:
Locking mechanism:
Switching element:
Switching principle:
Contact material:
Max. switching frequency:
Max. operating current
De-energized on trip:
Energized on trip:
Utilization category of
switching elements
to AC 15:
to DC 13:
Electrical service life:
Short circuit strength,
max. fusing:
Courant nominal de
court-circuit conditionnel
(rated conditional short circuit
current):
Mechanical life:
General Data
Operating mode
Mechanical life:
Temperature range
Standby current principle:
Load current principle:
Storage temperature:
Rated impulse voltage:
Rated insulation voltage:
Overvoltage category:
Pollution degree:
Connection:
Cross sections
min. / max.:
Cable entry with thread:
Intended use:
Mounting:
Test principles:
Rotating axis with redundant actuation
and mechanical interlock
PA + GF
Stainless steel V4A / AISI 316
(acc. to EN 10027-2;
1.4401; 1.4404; 1.4542;
1.4301; 1.4310)
F
2000 N
zh
IP 65
Standby current, failure locking-proof
Standby current or load current
100 / 250 mm/s
0.85 ... 1.1 U
N
(see solenoid derating graph)
5.5 W
1 NC contact,
2 antivalent changeover contacts
2 NC contacts + 1 C/O contact
IEC EN 60947-5-1 Appendix K
Changeover contact with forced opening
spring contact
Ag / AgSnO
2
360/h
2 A
1 A
1 A
0.5 A
5 x 10
switching cycles
6
2 A gG
1000 A
1 x 10
6
switching cycles
100% ED
- 25°C to + 45°C
- 25°C to + 45°C
- 25°C to + 60°C
0.8 kV
≤ 50 V
III
2
Cage clamp terminals
0.25 / 0.75 mm²
(with ferrules and sleeve
according to DIN 46228-4)
1 x M20x1.5
Up to max. cat. 4, PL e according
EN ISO 13849-1
To DIN EN 50041
EN ISO 13849-1:2015
DIN EN ISO 14119:2014-03
EN 60947-5-1:2017
GS-ET-15:2015-05
GS-ET-19:2015-05
GS-ET-31:2010-02

Safety Related Data

Data suitable for the PFHd summation method according
to EN ISO13849-1: 2016
Data
according to
EN
ISO13849-1:
2016
Category
2
PL
d
PFH
2.12199E-09 1.36918E-09 1.08914E-09 1.50183E-10
D
T
20
10D
CCF
65 ...100
required
B
2 x 10
6
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostics
Coverage
60 %
ratio DC
Test interval
1 / year
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met
PFH
:
When used as a „stand-alone unit" (not as part of a key trans-
D
fer system), the safety parameters in the table above apply
When used as part of a key transfer system:
- PFH
total STS/K system = SUM PFH
D
- Lowest category of a module = category of whole
STS/K system
- Lowest DC of a module = DC entire STS/K unit
!
If the design of a unit is changed, the safety-related data may also
change.
22
SAFEMASTER STS/K Basic unit ZRH01M/K / 01.03.20 en / 250A
ZRH01M/K
3
3
d
e
20
20
85 ...100
85 ...100
85 ...100
2 x 10
6
2 x 10
6
2 x 10
365
365
24
24
1
1
8760
8760
60 %
90 %
1 / year
1 / month
1 / month
+ ... PFH
D1
4
e
20
6
365
24
1
8760
99 %
Dn