Passive infrared detector with integrated dual band radio receiver for wireless extension of a traditional alarm system. It is 12V DC
supplied (by a control panel) and detects the infrared emission of people walking into covered area (about 12m - 100°), with adjustable
sensitivity, pulse counting and relay alarm output. Moreover, the inside receiver, mP controlled and supervised, can work with all
Silentron wireless detectors, giving out an alarm relay output, a tamper relay output and a supervision relay output.
To connect Expander PIR to a control panel , a cable with 7-11 single wires 0,15mm. is needed.
HOW TO USE EXPANDER PIR
The use of Expander PIR allows the installation of a hard-wired volumetric protection as well as a wireless protection on doors and
windows by means of opening/shock detectors SENSOR TOP and SENSOR SLIM, infrared barrier LASERBEAM or waterproof SILENT
PIR detector, for outdoor protection.
Expander PIR can store up to 32 self -programming detectors divided on 4 alarm zones. Test and alarm memory of each zone are
signalled by 4 red leds.
.
TECHNICAL FEATURES
Power supply: 10-14 V CC
In-out - covered area - dimensions: look at logic board picture and pictures 1 and 2
Radio receiver: frequency and features according to the Rules - approx. indication for security reasons
5055 model: superheterodyne receiver - sensitivity -105dbm - frequency about 400 MHz
5455 model: superherodyne receiver - sensitivity -105dbm - frequency about 400 MHz and 850 MHz
Programmable wireless detectors: 1 to 32 self -programming detectors on 4 alarm zones with 4 indication leds
Stock and operating temperature 0°C +55°C Protection degree: IP 41
Note 1: alarm due to opening of the Expander Pir box and to opening of boxes of all wireless detectors programmed.
Note 2: supervision alarm due to absence of radio signal from one or more wireless detectors during 8 hours. Antiscanner alarm due to
saturation of the receiver (model 5455: both receivers) during one minute permanently.
Position OFF of Dip-switch 4 blocks the functions.
Note 3: by connecting R terminal we have the alarm memory function on each led. Automatically reset when Expander is switched ON.
Program the input polarity (dip-switch 3) according with panel output: ON for positive output, OFF for negative.
If R terminal is not connected the "memory led" function will be stopped, but Expander Pir will work normally.
PROGRAMMING OF WIRELESS DETECTORS
1)
Supply Expander Pir by pressing P1 pushbutton: in this mode we reset all radio codes stored in the device: led A will blink.
2)
Press P2 to shift the zone A Ù B Ù C Ù D. Select the proper zone: the led will blink.
3)
Insert battery into the first wireless detector: the led will light 5 seconds and buzzer will sound, confirming the right programming.
4)
Insert battery into the second wireless detector and so on. When necessary, change the zone.
You can program the wireless detectors also after fixing Expander to a wall, because the zone shifting is automatic after 16 seconds
without transmissions. Program the detectors on A zone and wait for automatic shifting on B zone and so on.
Reset of programmed detectors: press P1 just one second to obtain the "programming status" - select the zone to reset by pressing
P2 and press P1 just 10 seconds. When led switches off for 5 sec. and buzzer sounds, all detectors on the zone are cancelled.
To add detectors press P1 just one second to obtain the "programming status" , select the zone and insert battery into the detector.
RELAY OUTPUT: all free contacts are NC and temporary open in case of alarm. The 5418 Sensor Silenya and 5015-16-17 Sensor Top
can be installed with "opening and closing door" function. In this case, if the door remains open, the relay output will be open all the
time.
Low battery of wireless detectors: a warning radio signal starts when the battery is low and Expander sounds 5 BEEP and the led of
the zone blinks. Moreover, the buzzer sounds at each arming-disarming of the system. Please change the battery asap in order to
avoid a supervision alarm.
Leds indications: a) temporary lighting = alarm
c) permanent blinking = low battery of a wireless detector
SILENTRON - ITALIA
Consumption:
40 mA standard
+ e -
10-14 V DC power supply
R
ON-OFF input from control panel - programmableby dip-switch 3
A1
free NC p.i.r. alarm output (0,1A max)
A2
free NC wireless detectors. alarm output (0,1A max)
TA
free NC anti-tamper alarm output (0,1A max) - look at note 1
AN
free NC antiscanner & supervision alarm output (0,1A max) - look at note 2
SENS.
passive infra-red sensitivity: set 50% for indoor coverage 20 sqm
and about 80% for indoor coverage 40sqm and more.
Dip-switch 4
OFF position for blocking antiscanner and supervision functions
Dip-switch 3
to program signal ON-OFF from the panel – Note 3
Dip-switch 2
P.I.R. pulse count:
Dip-switch 1
test ON: LED showing any alarm
P1
P2
Programming pushbuttons
b) permanent lighting = alarm memory
warnings led: 1 PIR led + 4 zone leds
Weight: 90 g
OFF = x1
ON = x3
COPYRIGHT SILENTRON
DS5455XA031008MV